Infrared heating of commercially available spray chambers to improve the analytical performance of inductively coupled plasma optical emission spectrometry

Abstract

In an attempt to improve the figures of merit of inductively coupled plasma optical emission spectrometry (ICPOES), a ceramic beaded infrared (IR) rope heater and a ceramic IR block heater were compared for heating each of a Scott double-pass spray chamber and a baffled cyclonic spray chamber up to 200 °C. A SeaSpray nebulizer was used in all cases. Following multivariate optimization, under compromise conditions for the determination of 29 elements, robustness, as assessed by the Mg II (280.270 nm)/Mg I (285.213 nm) emission intensity ratio, increased from 8.6 at room temperature to 12.0–12.6 for the four IR-heated systems. Furthermore, the detection limit improved by, on average, 2–3 fold with the rope heater and 5–10 fold with the block heater. In fact, for a given spray chamber, the improvement in detection limit was similar or less than the improvement in sensitivity with the IR rope heater, whereas the improvement in detection limit was significantly higher than that in sensitivity with the IR block heater, demonstrating the superior performance of IR heating over the combination of convective and IR heating provided by the IR rope heater. The best performance was achieved with a double-pass spray chamber and two IR block heaters, with detection limits improving, on average, by an order of magnitude compared to without heating, with a similar precision (on average, 1.3% relative standard deviation with IR blocks versus 1.5% without heating). In any case, under the resulting very robust conditions, all the IR-heated systems enabled the accurate analysis of a certified reference material of waste water by external calibration, without internal standardization or matrix-matching.

Graphical abstract: Infrared heating of commercially available spray chambers to improve the analytical performance of inductively coupled plasma optical emission spectrometry

Article information

Article type
Technical Note
Submitted
16 Jul 2018
Accepted
14 Sep 2018
First published
14 Sep 2018

J. Anal. At. Spectrom., 2018,33, 2008-2014

Infrared heating of commercially available spray chambers to improve the analytical performance of inductively coupled plasma optical emission spectrometry

A. Al Hejami and D. Beauchemin, J. Anal. At. Spectrom., 2018, 33, 2008 DOI: 10.1039/C8JA00239H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements