Detection and correction of matrix interference in inductively coupled plasma – time of flight mass spectrometry by means of aerosol dispersion

Abstract

The time-dependent ratio of two ion signals is used to indicate and correct for mass-dependent matrix interference in inductively coupled plasma-time of flight mass spectrometry. A plug of sample solution is injected into the nebulizer in an air carrier by means of a two-position flow-injection valve. Because of dispersion in the spray chamber, all species in the sample then yield the same time-dependent concentration profiles. In the absence of a matrix interference, the signal profiles also match, and produce a constant ratio. In contrast, the presence of a mass-dependent matrix interference causes the ratio of two ion signals to deviate from a constant value. The inconsistent ratio then serves as an indicator of the presence of a matrix interference. Four ion pairs (51V+/55Mn+, 59Co+/107Ag+, 55Mn+/208Pb+, and 52Cr+/208Pb+) are examined in the present study and reveal that ion pairs having a large mass difference serve best for the detection of heavy matrices (Ba and U here), which cause the greatest error. The optimal dilution factor to minimize the matrix interference can be identified as the time in the dispersion pattern when the matrix concentration in the aerosol drops to the point where the ratio becomes constant. In the current study, dilution factors of eight and ten are found to minimize matrix effects from Ba and U, respectively. The correct determined concentrations for all analytes are found at this optimal time when the matrix interference is minimized; discrepancies from the theoretical values are found to be from 5% to 8%. Without this correction method, 40% to 60% error in the measured analyte concentration arises under the influence of the same concentration of Ba or U matrices.

Graphical abstract: Detection and correction of matrix interference in inductively coupled plasma – time of flight mass spectrometry by means of aerosol dispersion

Article information

Article type
Technical Note
Submitted
22 Jan 2016
Accepted
04 May 2016
First published
19 May 2016

J. Anal. At. Spectrom., 2016,31, 1542-1548

Detection and correction of matrix interference in inductively coupled plasma – time of flight mass spectrometry by means of aerosol dispersion

Y. Cheung, S. J. Ray and G. M. Hieftje, J. Anal. At. Spectrom., 2016, 31, 1542 DOI: 10.1039/C6JA00022C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements