Issue 11, 2010

Laser beam profile influence on LIBS analytical capabilities: single vs. multimode beam

Abstract

Single vs. multimode laser beams have been compared for laser ablation on steel samples. Laser plasma properties and analytical capabilities (precision, limit of detection) were used as key parameters for comparison. Peak fluence at focal spot has been observed to be higher for Gaussian beam despite ∼14-fold lower pulse energy. A comparison of Gaussian and multimode beams with equal energy was carried out in order to estimate influence of beam profile only. Single mode lasing (Gaussian beam) results in better reproducibility of analytical signals compared to multimode lasing while laser energy reproducibility was the same for both cases. Precision improvements were attributed to more stable laser ablation due to better reproducibility of beam profile fluence at laser spot. Plasma temperature and electron density were higher for Gaussian laser beams. Calibration curves were obtained for four elements under study (Cr, Mn, Si, Cu). Two sampling (drilling and scanning procedures) and two optical detection schemes (side-view and optical fiber) were used to compare Gaussian and multimode beam profile influence on analytical capabilities of LIBS. We have found that multimode beam sampling was strongly influenced by surface effects (impurities, defects etc.). For all sampling and detection schemes, better precision was obtained if Gaussian beam was used for sampling. In case of single-spot sampling better limits of detection were achieved for multimode beam. If laser sources have the same wavelength and equal energy then quality of laser beam becomes a crucial parameter which determined laser ablation and analytical capabilities of LIBS.

Graphical abstract: Laser beam profile influence on LIBS analytical capabilities: single vs. multimode beam

Supplementary files

Article information

Article type
Paper
Submitted
07 May 2010
Accepted
29 Jul 2010
First published
30 Sep 2010

J. Anal. At. Spectrom., 2010,25, 1745-1757

Laser beam profile influence on LIBS analytical capabilities: single vs. multimode beam

V. Lednev, S. M. Pershin and A. F. Bunkin, J. Anal. At. Spectrom., 2010, 25, 1745 DOI: 10.1039/C0JA00017E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements