Use of single-collector and multi-collector ICP-mass spectrometry for isotopic analysis

Abstract

This article is intended as a tutorial review on the use of single-collector and multi-collector ICPMS for isotope ratio determination. The monitoring and quantification of both induced and natural differences in the isotopic composition of target elements is covered. The capabilities of various types of ICPMS instruments for isotope ratio measurements are addressed and issues, such as the occurrence of mass discrimination and detector dead time effects and appropriate ways of correcting for the biases they give rise to are discussed. Applications relying on induced changes include elemental assay via isotope dilution, tracer experiments with stable isotopes, aiming at a more profound insight into physical processes or (bio)chemical reactions, and nuclear applications. Attention is also paid to the origin of natural variations in the isotopic composition, with focus onto the mechanisms behind the isotopic variation for those elements for which isotopic analysis can be realized using ICP-mass spectrometry, i.e. the occurrence of radiogenic nuclides formed as a result of the decay of naturally occurring and long-lived radionuclides and mass fractionation as a result of thermodynamic and kinetic isotope fractionation effects. Geochronological dating via the Rb–Sr, U, Th–Pb, and Pb–Pb methods is briefly explained and also the use of Sr and Pb isotopic analysis for provenance determination studies is covered. Subsequently, applications based on isotopic analysis of elements showing a much narrower range of variation as a result of isotope fractionation are described. Next to provenance studies, such applications include the use of isotope ratios in geochemical, environmental and biomedical studies. Although it is not the intention to comprehensively review the literature, several examples of published applications are used to illustrate the capabilities of both single-collector and multi-collector ICPMS in this context. Thereby, attention is devoted both to widely accepted applications and to more ‘exotic’ applications, aiming at an extension of the application range.

Graphical abstract: Use of single-collector and multi-collector ICP-mass spectrometry for isotopic analysis

Article information

Article type
Tutorial Review
Submitted
24 Feb 2009
Accepted
31 Mar 2009
First published
24 Apr 2009

J. Anal. At. Spectrom., 2009,24, 863-886

Use of single-collector and multi-collector ICP-mass spectrometry for isotopic analysis

F. Vanhaecke, L. Balcaen and D. Malinovsky, J. Anal. At. Spectrom., 2009, 24, 863 DOI: 10.1039/B903887F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements