Issue 10, 2009

Surface plasmon resonance biosensor for direct detection of antibodies against human growth hormone

Abstract

A direct, label-free detection method of antibodies against the human growth hormone (anti-HGH) using a surface plasmon resonance (SPR) biosensor is reported. The sensing surface of the surface plasmon resonance biosensor chip (SPR-chip) was modified by covalent coupling of the human growth hormone (HGH) to the self-assembled monolayer of 11-mercaptoundecanoic acid (MUA). HGH was immobilized viaprimary amine groups after activation of the MUAcarboxyl groups with a mixture of N-hydroxysuccinimide (NHS), and N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide hydrochloride (EDC). The specific binding of monoclonal anti-HGH antibody on the HGH-modified surface was examined in the concentration range from 0.25 nM to 10 µM. The experimentally observed detection minimum for anti-HGH was 2.47 nM. A single immunoassay cycle could be done within 30 min including the HGH and anti-HGH association, HGH/anti-HGH complex dissociation and surface regeneration steps. The SPR biosensor response for repeatable detections of anti-HGH was highly reproducible and very stable. On the SPR-chip the formed HGH and anti-HGH complex (HGH/anti-HGH) could be gently dissociated and the sensing surface might be regenerated by 50 mM NaOH and 0.5% sodium dodecylsulfate (SDS) solution. Any changes in the original baseline level were detected during the 40 detection–regeneration cycles. This means that damage of the immobilized HGH-based sensitive layer during regeneration was minimal. It was demonstrated that the developed SPR-chip could be stored for at least 21 days before use without considerable loss of sensitivity towards anti-HGH.

Graphical abstract: Surface plasmon resonance biosensor for direct detection of antibodies against human growth hormone

Article information

Article type
Paper
Submitted
09 Apr 2009
Accepted
17 Jul 2009
First published
31 Jul 2009

Analyst, 2009,134, 2051-2057

Surface plasmon resonance biosensor for direct detection of antibodies against human growth hormone

A. Kausaite-Minkstimiene, A. Ramanaviciene and A. Ramanavicius, Analyst, 2009, 134, 2051 DOI: 10.1039/B907315A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements