Issue 10, 2003

A comparison of 266 nm, 213 nm and 193 nm produced from a single solid state Nd:YAG laser for laser ablation ICP-MS

Abstract

Laser ablation using wavelengths of 266 nm, 213 nm and 193 nm as a sampling method for ICP-MS was compared. Unlike previous studies, this was performed under essentially identical laser ablation conditions with the exception of wavelength. This was achieved by using a single solid state laser source (1064 nm Nd:YAG) for harmonic generation together with sum frequency mixing and optical parametric oscillation. Experiments were carried out on the NIST 600 series silicate glasses. Particle size distributions for all three wavelength were measured and increased in the order 193 nm < 213 nm < 266 nm. This effect is related to the absorption behaviour of the sample opaque < transparent at each wavelength. The change towards larger particle sizes with increasing wavelength is influencing the noise in the transient signals and their intensity ratios. A smaller number of particles with diameters of >150 nm are produced in comparison to longer wavelengths when ablating with 193 nm. Due to the decreased amount of particles above 0.15 µm vaporisation induced elemental fractionation within the ICP, especially for more transparent samples is reduced. Data on the behaviour of 213 nm ablation and resulting ICP-MS response demonstrated that this wavelength is intermediate between 193 nm and 266 nm, but biased towards 193 nm for more opaque samples and biased towards 266 nm for those more transparent. This study (maintaining laser parameter constant and not exceeding depth to diameter ratios of 2∶1) shows that the wavelengths in first instance are responsible for particle size distribution and that their distribution leads to enhanced vaporisation, atomisation and ionisation effects within the ICP. Until now, only 193 nm produced particle sizes (as shown for the selection of silicate samples) can be stoichiometrically converted into ions using common ICP-MS instruments.

Article information

Article type
Paper
Submitted
15 May 2003
Accepted
15 Jul 2003
First published
29 Jul 2003

J. Anal. At. Spectrom., 2003,18, 1224-1230

A comparison of 266 nm, 213 nm and 193 nm produced from a single solid state Nd:YAG laser for laser ablation ICP-MS

M. Guillong, I. Horn and D. Günther, J. Anal. At. Spectrom., 2003, 18, 1224 DOI: 10.1039/B305434A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements