Issue 4, 2000

Abstract

Calibration experiments were performed on a commercially available double focusing magnetic sector single detector ICP-MS instrument to evaluate its potential for accurate isotope abundance ratio measurements down to the 1 pg g−1 isotope concentration level (without involving any preconcentration step). Its performance, for isotope abundance ratios varying over almost three orders of magnitude from ≈1∶1 to ≈1∶500, was checked using the IRMM-072 series of Isotopic Reference Materials. Routine experimental settings were applied and remained unchanged for the entire series of experiments. It is shown that all the certified ratios (certified to within 0.03% expanded combined uncertainty, k = 2) could be matched experimentally within the expanded (k = 2) combined uncertainty of the measurements (from ±0.11 to ±0.33% for 233U/235U, and from ±0.16 to ±0.31% for 233U/238U). For 1∶1 ratios (235U/238U) a 0.05% precision could be reproducibly obtained of which only 33% could be accounted for by Poisson statistics, whereas for 1∶500 ratios a 0.16% precision was obtained which could be completely explained by the same Poisson theory. In addition to the experimental precision other possible sources of uncertainty were investigated. The way isotope abundance ratios are measured (acceleration voltage is varied while the magnetic field is kept constant) is discussed as a potential extra source of mass discrimination. The crucial importance of a proper correction for dead-time effects is demonstrated. Finally, the hypothesis of a contamination with natural uranium that would have biased the results could be ruled out for all samples.

Article information

Article type
Paper
Submitted
01 Sep 1999
Accepted
24 Nov 1999
First published
03 Feb 2000

J. Anal. At. Spectrom., 2000,15, 353-358

Examination of the performance exhibited by a single detector double focusing magnetic sector ICP-MS instrument for uranium isotope abundance ratio measurements over almost three orders of magnitude and down to pg g−1 concentration levels

C. R. Quétel, T. Prohaska, M. Hamester, W. Kerl and P. D. P. Taylor, J. Anal. At. Spectrom., 2000, 15, 353 DOI: 10.1039/A907084B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements