Viscosities of gaseous argon–nitrogen mixtures
Abstract
The viscosities of gaseous argon–nitrogen mixtures have been measured in the temperature range 120–1600 K using a capillary flow technique. The results are considered to be accurate to ±1% and are used to calculate interaction viscosity coefficients and binary diffusion coefficients for the mixtures.