Issue 1270, 1982

Determination of formaldehyde vapour in the atmospheres of clinical laboratories using chromotropic acid

Abstract

Ethanol and xylene vapours were found to interfere with the determination of formaldehyde vapour by the chromotropic acid method, whether water or a mixture of chromotropic and sulphuric acids were used as the scrubbing solution. The interference can be removed by a porous polymer sorbent, Tenax GC. Thus, with a Tenax GC pre-trap, the chromotropic acid method can be applied to the determination of formaldehyde vapour in clinical laboratories where alcohol and xylene vapours are often encountered. The advantages of selecting chromotropic-sulphuric acid instead of water as the scrubbing solution are discussed.

Article information

Article type
Paper

Analyst, 1982,107, 30-34

Determination of formaldehyde vapour in the atmospheres of clinical laboratories using chromotropic acid

C. W. Lee, Y. S. Fung and K. W. Fung, Analyst, 1982, 107, 30 DOI: 10.1039/AN9820700030

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements