Abstract

An improved chemical method is developed to accurately measure the W isotopic compositions of silicate samples with a precision of better than ±0.05ε on ε182W. Compared with the conventional method, two developments of this method mainly include the sample digestion process that is modified to better W dissolution from the co-precipitations and the W separation procedure. The optimized extraction chromatography using TEVA resin is designed to more efficiently separate W from Ti, Zr and Hf after the first-stage cation-exchange procedure with the percent recovery of W more than 85%. The blank during the whole procedure is less than 0.3 ng and is negligible for W isotopic analysis. The W isotopic ratios of Alfa Aesar W standard solution and a variety of silicate reference materials, i.e., RGM-2, GSP-2, AGV-2, JB-3, BCR-2 and BHVO-2, are measured by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). RGM-2, GSP-2, AGV-2, JB-3 and BCR-2 have normal ε182W values, identical to that of the terrestrial Alfa Aesar W standard, whereas BHVO-2 has a negative ε182W value of −0.09 ± 0.05 (2SD, N = 10). The duplicate measurements of Alfa Aesar W standard solution RGM-2 and BHVO-2 show that the external reproducibility of ε182W is usually better than 5 ppm (2SD), which is the most precise among the published data measured by MC-ICPMS and can be comparable to the precision acquired by negative thermal ionization mass spectrometry (N-TIMS) (about 5 ppm). All these results show that our new method provides an efficient way to precisely measure W isotopic compositions of silicate materials. It provides a widely useful tool to reveal the earliest history of the silicate earth and offers the ability to resolve sub-million-year age differences in meteorites.

Graphical abstract: An improved extraction chromatographic purification of tungsten from a silicate matrix for high precision isotopic measurements using MC-ICPMS

Back to tab navigation

Supplementary files

Publication details

The article was received on 29 Jan 2018, accepted on 06 Feb 2018 and first published on 06 Feb 2018


Article type: Paper
DOI: 10.1039/C8JA00024G
Citation: J. Anal. At. Spectrom., 2018,33, 569-577
  •   Request permissions

    An improved extraction chromatographic purification of tungsten from a silicate matrix for high precision isotopic measurements using MC-ICPMS

    Q. Mei, J. Yang and Y. Yang, J. Anal. At. Spectrom., 2018, 33, 569
    DOI: 10.1039/C8JA00024G

Search articles by author

Spotlight

Advertisements