A Comparison of Signal Suppression and Particle Size Distributions for ns- and fs-LA for metallic samples by LA-ETV-ICPMS

Abstract

The influence of thermal treatment of laser-generated aerosols in a graphite furnace electrothermal vaporization (ETV) unit was investigated. Changes in chemical composition and particle size distribution (PSD) of aerosols generated by nanosecond (ns-LA) and femtosecond (fs-LA) ablation of Cu, Zn, brass and Ta were monitored as a function of the graphite furnace temperature via inductively coupled plasma mass spectrometry (ICPMS) and with an optical particle counter (OPC). Morphology changes were investigated by recording SEM images of filter-collected material. With increasing furnace temperature, the ICPMS signals of all elements decreased and the onset temperatures of the suppression followed the order of the boiling points of the elements. Ablation with fs-LA generally showed a continuous signal decrease with increasing temperature. When ablating Zn with ns-LA, a discontinuity was introduced in the suppression profile, which was related to the PSDs of the original aerosols. Between 60 nm and 1 μm, these were generally broader when using fs-LA for ablation of Zn, Cu and brass. When heating the aerosol, the morphology and PSD of the aerosols indicated that melting causes the nanoparticles’ agglomerate to collapse into lumps of spherical shape. The discontinuity in the suppression profiles is interpreted to originate from the contribution of the large particles that are not evaporating and give a continuous contribution to the ion signals. Heating of the Ta-aerosols only resulted in a slight signal suppression, while SEM images revealed the presence of particles of larger sizes that were most likely formed from molten NPs and agglomerates. The thermal treatment opens a unique way for a selective removal of elements forming spectral interferences when using LA-ICPMS for spatially resolved solid sampling. In this study, the Zn-signal from the brass sample could be lowered by selective evaporation by more than 3 orders of magnitude, while Cu was still quantitatively retained in the aerosol. This separation was slightly more efficient when using fs-LA, which is most likely the result of the larger fraction of μm-sized particle in the ns-LA aerosols studied here.

Back to tab navigation

Supplementary files

Publication details

The article was received on 05 May 2017, accepted on 08 Aug 2017 and first published on 08 Aug 2017


Article type: Paper
DOI: 10.1039/C7JA00176B
Citation: J. Anal. At. Spectrom., 2017, Accepted Manuscript
  •   Request permissions

    A Comparison of Signal Suppression and Particle Size Distributions for ns- and fs-LA for metallic samples by LA-ETV-ICPMS

    H. C. Yilmaz and B. Hattendorf, J. Anal. At. Spectrom., 2017, Accepted Manuscript , DOI: 10.1039/C7JA00176B

Search articles by author

Spotlight

Advertisements