Effects of H2O- and O2-containing He carrier gases on the 206Pb/238U system bias and down-hole fractionation in LA-ICPMS of zircon

Author affiliations

Abstract

This paper deals with the effects the addition of H2O or O2 to He aerosol carrier gas has on 206Pb/238U ratios during laser ablation inductively-coupled plasma mass spectrometry (LA-ICPMS) of natural zircon and synthetic silicate glass. The following parameters were studied: (i) system bias defined as constant but LA-ICPMS system-dependent shifts in 206Pb/238U ratios, (ii) down-hole fractionation given by the slope of the 206Pb/238U ratio vs. LA time, and (iii) the sum of (i) and (ii) referred to as the overall elemental fractionation. To isolate and study changes of 206Pb/238U ratios arising independently from either LA sampling or ICPMS analysis of the generated aerosols, a diffusion-based gas exchange device was used. The supply of He + O2 caused relative changes in mean 206Pb/238U values and temporal gradients due to the LA process of less than 40%. By contrast, addition of H2O to the He carrier gas changed 206Pb/238U ratios by up to 150% through processes occurring during LA as well as ICPMS analysis. Here, the opposing temporal gradients of 206Pb/238U ratios canceled out at relative humidity levels close to the saturation vapor pressure under ambient lab conditions, i.e., 20 °C room temperature. As a consequence, changes in 206Pb/238U ratios caused by down-hole fractionation could be suppressed. However, the admixture of H2O also affected the system bias at the same time, resulting in increased offsets in 206Pb/238U ratios such that the accuracy of LA-ICPMS analyses worsened by up to 6% when applied to the age determination of zircon. Neither worsening nor significant improvements in the accuracy of 206Pb/238U ages were observed in the case of LA-ICPMS using He + O2 carrier gas mixtures.

Graphical abstract: Effects of H2O- and O2-containing He carrier gases on the 206Pb/238U system bias and down-hole fractionation in LA-ICPMS of zircon

Back to tab navigation

Supplementary files

Publication details

The article was received on 11 Jan 2017, accepted on 06 Sep 2017 and first published on 06 Sep 2017


Article type: Paper
DOI: 10.1039/C7JA00017K
Citation: J. Anal. At. Spectrom., 2017, Advance Article
  •   Request permissions

    Effects of H2O- and O2-containing He carrier gases on the 206Pb/238U system bias and down-hole fractionation in LA-ICPMS of zircon

    S. Allner, J. Koch, S. E. Jackson and D. Günther, J. Anal. At. Spectrom., 2017, Advance Article , DOI: 10.1039/C7JA00017K

Search articles by author

Spotlight

Advertisements