Jump to main content
Jump to site search


Development of on-line UV-induced volatile species generation for selenium speciation [Se(IV) and SeCN] by ion chromatography-inductively coupled plasma mass spectrometry in petroleum refinery wastewater

Author affiliations

Abstract

An on-line UV-induced vapor generation method has been developed that allows simultaneous conversion of selenocyanate [SeCN] and [Se(IV)] to volatile species for their subsequent determination by IC-ICPMS in petroleum refinery wastewater with improved detection limits. The species present in the sample were separated on an anion-exchange column using a step gradient with NaOH as the eluent, and were subsequently converted to their volatile forms by UV irradiation in the presence of a mixture of HCOOH–HNO3 followed by quantitative determination using an ICP-MS. Employing a 200 μL sample injection loop, the species separation was achieved within 7 min and with the best detection limits achieved at 0.01 μg L−1 and 0.06 μg L−1 for SeCN and Se(IV) respectively while the reproducibilities achieved for retention times and peak areas in the chromatograms were better than 1.3% and 5.0% respectively. The method was successfully employed to study the quantitative speciation of selenium in three petroleum refinery wastewaters with accuracy of the results obtained validated by two independent methods. Further validation was carried out by a standard addition method and also by analysing a certified reference material BCR-713, wastewater effluent. Quantitative recoveries (>95%) were observed for both Se(IV) and SeCN in refinery wastewater.

Graphical abstract: Development of on-line UV-induced volatile species generation for selenium speciation [Se(iv) and SeCN−] by ion chromatography-inductively coupled plasma mass spectrometry in petroleum refinery wastewater

Back to tab navigation
Please wait while Download options loads

Publication details

The article was received on 28 Nov 2016, accepted on 01 Mar 2017, published on 01 Mar 2017 and first published online on 01 Mar 2017


Article type: Paper
DOI: 10.1039/C6JA00427J
Citation: J. Anal. At. Spectrom., 2017, Advance Article
  •   Request permissions

    Development of on-line UV-induced volatile species generation for selenium speciation [Se(IV) and SeCN] by ion chromatography-inductively coupled plasma mass spectrometry in petroleum refinery wastewater

    K. Chandrasekaran, N. Garg and D. Karunasagar, J. Anal. At. Spectrom., 2017, Advance Article , DOI: 10.1039/C6JA00427J

Search articles by author