Comparison of fast electron transfer kinetics at platinum, gold, glassy carbon and diamond electrodes using Fourier-transformed AC voltammetry and scanning electrochemical microscopy

Author affiliations

Abstract

Heterogeneous electron transfer (ET) processes at electrode/electrolyte interfaces are of fundamental and applied importance and are extensively studied by a range of electrochemical techniques, all of which have various attributes but also limitations. The present study focuses on the one-electron oxidation of tetrathiafulvalene (TTF) and reduction of tetracyanoquinodimethane (TCNQ) in acetonitrile solution by two powerful electrochemical techniques: Fourier-transformed large amplitude alternating current voltammetry (FTACV); and scanning electrochemical microscopy (SECM), both of which are supported by detailed theoretical models. At conventional Pt, Au and glassy carbon (GC) electrode materials, the apparent (overall) charge transfer kinetic values determined by FTACV give standard ET rate constants, k0FTACV, that are fast and close to the reversible limit. They are in good agreement with highly localised k0SECM measurements determined by SECM under conditions of high mass transport rates. In contrast, the impact of both the complex heterogeneous surface of polycrystalline boron doped diamond (pBDD) and degenerate p-type doping results in a range of k0SECM values across the electrode surface compared to the overall k0FTACV measured for both processes studied. Moreover, the reduced availability of charge carriers at the electrode surface, at each energy state, compared to a metal, which decreases as the potential becomes more negative, results in lower k0 values at pBDD than Pt, Au and GC. The measurement technique also has an influence: SECM measurements are made at much higher local current density than FTACV, and for TCNQ/TCNQ˙, which has the more negative formal potential, limited charge carrier availability results in k0FTACV > k0SECM, with unusual apparent charge transfer coefficients and voltammetric waveshapes from SECM. These data thus highlight the importance of understanding the influence of the measurement technique and further demonstrate how ET kinetics at pBDD differ from conventional electrodes, in this case for processes in an organic solvent, which has received much less attention compared to aqueous systems for studies with pBDD.

Graphical abstract: Comparison of fast electron transfer kinetics at platinum, gold, glassy carbon and diamond electrodes using Fourier-transformed AC voltammetry and scanning electrochemical microscopy

Back to tab navigation
Please wait while Download options loads

Supplementary files

Publication details

The article was received on 13 Feb 2017, accepted on 06 Mar 2017, published on 06 Mar 2017 and first published online on 06 Mar 2017


Article type: Paper
DOI: 10.1039/C7CP00968B
Citation: Phys. Chem. Chem. Phys., 2017, Advance Article
  •   Request permissions

    Comparison of fast electron transfer kinetics at platinum, gold, glassy carbon and diamond electrodes using Fourier-transformed AC voltammetry and scanning electrochemical microscopy

    S. Tan, R. A. Lazenby, K. Bano, J. Zhang, A. M. Bond, J. V. Macpherson and P. R. Unwin, Phys. Chem. Chem. Phys., 2017, Advance Article , DOI: 10.1039/C7CP00968B

Search articles by author