Packed-Nanofiber Solid Phase Extraction Coupled with HPLC for Determination of Chloramphenicol in Milk

Abstract

A sensitive analytical method based on packed-nanofiber solid phase extraction (PFSPE) and high performance liquid chromatography (HPLC) has been developed for determining chloramphenicol (CAP) in milk. Polystyrene-polyvinylpyrrolidone (PS-PVP) composite nanofibers were fabricated by electrospinning and utilized to prepare home-made extraction device. With optimal conditions, a 12 min of HPLC analysis with isocratic elution was successfully applied to determine CAP in milk. The analyte was separated well and blank milk did not disturb determination, and the linearity is good at the range of 0.5-10 μg/L, the recoveries were in the range of 97.5 %-104.0 %. The intra-day and inter-day RSDs for spiked samples was respectively 4.6 %-7.1 % and 8.4 %, all below 10 %. The limit of detection (LOD) was determined to be 0.2 μg/L. Due to its simplicity, low-cost and time-saving, the method has a potential to be applied to monitor antibiotic residues in dairy products with complex matrices.

Back to tab navigation

Supplementary files

Publication details

The article was received on 10 May 2017, accepted on 10 Sep 2017 and first published on 11 Sep 2017