Jump to main content
Jump to site search

Issue 18, 2017
Previous Article Next Article

Improved assessment of accuracy and performance indicators in paper-based ELISA

Author affiliations

Abstract

Paper-based devices are an excellent match for low-cost point-of-care testing (POCT) tools. Their user-friendliness, portability, and short time of analysis, coupled with ease of local manufacture make these devices the best option for inexpensive diagnostic testing tools. However, despite all their positive features, these low-cost diagnostic devices must present good performance indicators, such as sensitivity, specificity, and accuracy. We developed and validated a paper-based ELISA for toxoplasmosis diagnosis through the detection of Toxoplasma gondii immunoglobulin G (IgG) antibodies in 100 human serum samples. From among the different ways to define the cut-off value, we chose Youden's J index (cut-off = 21.73 A.U.), which presented a higher sensitivity value. Our paper-based assay presented a sensitivity of 0.96, a specificity of 0.87, and a gray zone comprising 16 samples (±15% of the cut-off value, with 3 false positive outputs). The accuracy of the test was estimated by using ROC curves (AUC = 0.97). We also created a macro in Microsoft Excel® to estimate the accuracy of the test (m-Accuracy) based on a non-parametric method, which evidenced a value = 0.88, which classifies our test as moderately to highly accurate. We also provide the m-Accuracy macro for download and the paper-based microplate designs for printing, in order to collaborate with the scientific community and facilitate further studies using this platform. The improvement of these diagnostic tools can bring this technology for those who need it, contributing to population health and well-being.

Graphical abstract: Improved assessment of accuracy and performance indicators in paper-based ELISA

Back to tab navigation

Supplementary files

Publication details

The article was received on 24 Feb 2017, accepted on 10 Mar 2017 and first published on 22 Mar 2017


Article type: Paper
DOI: 10.1039/C7AY00505A
Citation: Anal. Methods, 2017,9, 2644-2653
  • Open access: Creative Commons BY-NC license
  •   Request permissions

    Improved assessment of accuracy and performance indicators in paper-based ELISA

    T. Mazzu-Nascimento, G. G. Morbioli, L. A. Milan, D. F. Silva, F. C. Donofrio, C. A. Mestriner and E. Carrilho, Anal. Methods, 2017, 9, 2644
    DOI: 10.1039/C7AY00505A

    This article is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported Licence. Material from this article can be used in other publications provided that the correct acknowledgement is given with the reproduced material and it is not used for commercial purposes.

    Reproduced material should be attributed as follows:

    • For reproduction of material from NJC:
      [Original citation] - Published by The Royal Society of Chemistry (RSC) on behalf of the Centre National de la Recherche Scientifique (CNRS) and the RSC.
    • For reproduction of material from PCCP:
      [Original citation] - Published by the PCCP Owner Societies.
    • For reproduction of material from PPS:
      [Original citation] - Published by The Royal Society of Chemistry (RSC) on behalf of the European Society for Photobiology, the European Photochemistry Association, and RSC.
    • For reproduction of material from all other RSC journals:
      [Original citation] - Published by The Royal Society of Chemistry.

    Information about reproducing material from RSC articles with different licences is available on our Permission Requests page.

Search articles by author

Spotlight

Advertisements