Improved solid-phase extraction protocol and sensitive quantification of six microcystins in water using an HPLC-orbitrap mass spectrometry system

Author affiliations

Abstract

A solid-phase extraction (SPE) protocol was developed and combined with HPLC-ESI-MS for the quantification of common cyanobacterial toxins, microcystins (MCs), in water. An HPLC binary gradient was established for the separation of MC-LR, MC-YR, MC-RR, MC-LA, MC-LW, and MC-LF, while quantification of MCs in MC-spiked HPLC-grade water, tap water, and lake water was achieved in selected ion monitoring (SIM) mode using a high-resolution Orbitrap Fusion Tribrid mass spectrometer. All MC ions were detected with high mass accuracy of ≤1.61 ppm using the orbitrap mass analyzer, and MCs were quantified using external calibration based on LC-SIM-MS peak areas of the monoisotopic MC ions. The LOQs of MC-LA, MC-LW, and MC-LF in water using LC-SIM-MS were ∼25 ng L−1 while LOQs of MC-RR, MC-LR and MC-YR in water were ∼10 ng L−1. After the purification and preconcentration of MCs by SPE, LOQs of MC-LA, MC-LW and MC-LF were improved to ∼1 ng L−1 and LOQs of MC-RR, MC-LR and MC-YR were improved to ∼600 pg L−1 in tap water and lake water. The percent recoveries of MCs after SPE and sample preconcentration were in the range from 97.1% to 100.9% with a relative standard deviation (RSD) of ≤5.0%, indicating that this is one of the most efficient and reproducible SPE procedures for recovery of MCs from aqueous solutions. Additionally, a parallel LC-tandem mass spectrometry (MS/MS) method was established for the structural identification of MCs. Overall, the MC purification and preconcentration method developed and LC-SIM-MS enable sensitive, selective, and reproducible identification and quantification of MCs in water using the MS and MS/MS capabilities of a high-mass accuracy orbitrap mass spectrometer.

Graphical abstract: Improved solid-phase extraction protocol and sensitive quantification of six microcystins in water using an HPLC-orbitrap mass spectrometry system

Back to tab navigation
Please wait while Download options loads

Supplementary files

Publication details

The article was received on 27 Dec 2016, accepted on 12 Feb 2017 and first published on 13 Feb 2017


Article type: Paper
DOI: 10.1039/C6AY03459D
Citation: Anal. Methods, 2017,9, 2021-2030