A portable microfluidic system for rapid measurement of the erythrocyte sedimentation rate

Author affiliations

Abstract

The erythrocyte sedimentation rate (ESR) is a frequently used 30 min or 60 min clinical test for screening of several inflammatory conditions, infections, trauma, and malignant diseases, as well as non-inflammatory conditions including prostate cancer and stroke. Erythrocyte aggregation (EA) is a physiological process where erythrocytes form face-to-face linear structures, called rouleaux, at stasis or low shear rates. In this work, we proposed a method for ESR measurement from EA. We developed a microfluidic opto-electro-mechanical system, using which we experimentally showed a significant correlation (R2 = 0.86) between ESR and EA. The microfluidic system was shown to measure ESR from EA using fingerprick blood in 2 min. 40 μl of whole blood is filled in a disposable polycarbonate cartridge which is illuminated with a near infrared emitting diode. Erythrocytes were disaggregated under the effect of a mechanical shear force using a solenoid pinch valve. Following complete disaggregation, transmitted light through the cartridge was measured using a photodetector for 1.5 min. The intensity level is at its lowest at complete disaggregation and highest at complete aggregation. We calculated ESR from the transmitted signal profile. We also developed another microfluidic cartridge specifically for monitoring the EA process in real-time during ESR measurement. The presented system is suitable for ultrafast, low-cost, and low-sample volume measurement of ESR at the point-of-care.

Graphical abstract: A portable microfluidic system for rapid measurement of the erythrocyte sedimentation rate

Back to tab navigation
Please wait while Download options loads

Publication details

The article was received on 16 Aug 2016, accepted on 10 Nov 2016 and first published on 10 Nov 2016


Article type: Paper
DOI: 10.1039/C6LC01036A
Citation: Lab Chip, 2016,16, 4682-4690
  •   Request permissions

    A portable microfluidic system for rapid measurement of the erythrocyte sedimentation rate

    Z. Isiksacan, O. Erel and C. Elbuken, Lab Chip, 2016, 16, 4682
    DOI: 10.1039/C6LC01036A

Search articles by author