Issue 2, 2015

Evaluation of bioaerosol exposures during hospital bronchoscopy examinations

Abstract

During hospital bronchoscopy examinations, aerosols emitted from the patient's during coughing can be found suspended in the ambient air. The aerosols can contain pathogenic microorganisms. Depending on their size, these microorganisms can remain in the air for a long time. The objective of this study was to measure the sizes and concentrations of the biological and non-biological particles produced during bronchoscopy examinations, and to propose preventive or corrective measures. Two bronchoscopy rooms were studied. An aerodynamic particle sizer (UV-APS) was used to establish the concentrations of the particles present and their size distributions. This instrument determines the aerodynamic diameter of the aerosols and can distinguish fluorescent (bioaerosols) and non-fluorescent particles. Reference concentrations were measured before the start of the examinations (morning background concentrations). They were used as comparison levels for the concentrations measured during and at the end of the bronchoscopies. In parallel, computational fluid dynamics (CFD) made it possible to isolate and understand different factors that can affect the concentration levels in bronchoscopy rooms. The concentrations of the non-fluorescent and fluorescent particles (bioaerosols) were significantly higher ( p ≤ 0.05) during the bronchoscopy examinations than the reference concentrations. For the investigated factors, the bioaerosol concentrations were significantly higher during bronchoscope insertion tasks. The time required at the end of the day for the bioaerosols to reach the morning reference concentrations was about fifteen minutes. The average particle sizes were 2.9 μm for the fluorescent particles (bioaerosols) and 0.9 μm for the non-fluorescent particles. Our models based on computational fluid dynamics (CFD) enabled us to observe the behaviour of aerosols for the different rooms.

Graphical abstract: Evaluation of bioaerosol exposures during hospital bronchoscopy examinations

  • This article is part of the themed collection: AIRMON 2014

Article information

Article type
Paper
Submitted
27 Jun 2014
Accepted
23 Sep 2014
First published
23 Sep 2014

Environ. Sci.: Processes Impacts, 2015,17, 288-299

Author version available

Evaluation of bioaerosol exposures during hospital bronchoscopy examinations

J. Lavoie, G. Marchand, Y. Cloutier, S. Hallé, S. Nadeau, C. Duchaine and G. Pichette, Environ. Sci.: Processes Impacts, 2015, 17, 288 DOI: 10.1039/C4EM00359D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements