Issue 6, 2015

Investigation of the DNA target design parameters for effective hybridization-induced aggregation of particles for the sequence-specific detection of DNA

Abstract

In a recent publication, we presented a label-free method for the detection of specific DNA sequences through the hybridization-induced aggregation (HIA) of a pair of oligonucleotide-adducted magnetic particles. Here we show, through the use of modified hardware, that we are able to simultaneously analyze multiple (4) samples, and detect a 26-mer ssDNA sequence at femtomolar concentrations in minutes. As such, this work represents an improvement in throughput and a 100-fold improvement in sensitivity, compared to that reported previously. Here, we also investigate the design parameters of the target sequence, in an effort to maximize the sensitivity of HIA and to use as a guide in future applications of this work. Modifications were made to the original 26-mer oligonucleotide sequence to evaluate the effects of: (1) non-complementary flanking bases, (2) target sequence length, and (3) single base mismatches on aggregation response. The aggregation response decreased as the number of the non-complementary flanking bases increased, with only a five base addition lowering the LOD by four orders of magnitude. Low sensitivity was observed with short sequences of 6 and 10 complementary bases, which were only detectable at micromolar concentrations. Target sequences with 20, 26 or 32 complementary bases provided the greatest sensitivity and were detectable at femtomolar concentrations. Additionally, HIA could effectively differentiate sequences that were fully complementary from those containing 1, 2 or 3 single base mismatches at micromolar concentrations. The robustness of the HIA system to other buffer components was explored with nine potential assay interferents that could affect hybridization (aggregation) or falsely induce aggregation. Of these, purified BSA and lysed whole blood induced a false aggregation. None of the interferents inhibited aggregation when the hybridizing target was added. Having delineated the fundamental parameters affecting HIA-target hybridization, and demonstrating that HIA had the selectivity to detect single base mismatches, this fluor-free end-point detection has the potential to become a powerful tool for microfluidic DNA detection.

Graphical abstract: Investigation of the DNA target design parameters for effective hybridization-induced aggregation of particles for the sequence-specific detection of DNA

Article information

Article type
Paper
Submitted
13 Nov 2014
Accepted
31 Jan 2015
First published
12 Feb 2015

Analyst, 2015,140, 2008-2015

Author version available

Investigation of the DNA target design parameters for effective hybridization-induced aggregation of particles for the sequence-specific detection of DNA

B. C. Strachan, H. S. Sloane, J. C. Lee, D. C. Leslie and J. P. Landers, Analyst, 2015, 140, 2008 DOI: 10.1039/C4AN02101K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.