Issue 11, 2014

Cation-selective electropreconcentration

Abstract

A cation-selective microfluidic sample preconcentration system is described. The cation sample was electropreconcentrated using a reversed-direction electroosmotic flow (EOF) and an anion-permselective filter, where an electric double layer (EDL) overlap condition existed. The anion-permselective filter between microchannels was fabricated by three different methods: 1) extending a positively charged, nanoporous, polymer membrane by photopolymerization of poly(diallyldimethylammonium chloride) (PDADMAC); 2) etching a nanochannel and then coating it with a positively-charged monomer, N-[3-(trimethoxysilyl)propyl]-N′-(4-vinylbenzyl)ethylenediamine hydrochloride (TMSVE); and, 3) etching a nanochannel and then coating it with a positively-charged, pre-formed polymer, polyE-323. The EOF direction in the microchannel was reversed by both TMSVE and polyE-323 coatings. The cation-selective preconcentration was investigated using charged fluorescent dyes and tetramethylrhodamine isothiocyanate (TRITC)-tagged peptides/proteins. The preconcentration in the three different systems was compared with respect to efficiency, dependence on buffer concentration and pH, tolerable flow rate, and sample adsorption. Both TMSVE- and polyE-323-coated nanochannels showed robust preconcentration at high flow rates, whereas the PDADMAC membrane maintained anion-permselectivity at higher buffer concentrations. The TMSVE-coated nanochannels showed a more stable preconcentration process, whereas the polyE-323-coated nanochannels showed a lower peptide sample adsorption and robust efficiency under a wide range of buffer pHs. The system described here can potentially be used for the preconcentration of cationic peptides/proteins on microfluidic devices for subsequent analyses.

Graphical abstract: Cation-selective electropreconcentration

Supplementary files

Article information

Article type
Technical Innovation
Submitted
08 Jan 2014
Accepted
26 Feb 2014
First published
26 Feb 2014

Lab Chip, 2014,14, 1811-1815

Author version available

Cation-selective electropreconcentration

I. H. Shin, K. Kim, J. Kim, H. C. Kim and H. Chun, Lab Chip, 2014, 14, 1811 DOI: 10.1039/C4LC00024B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements