Efficacy of surface sampling methods for different types of beryllium compounds

Abstract

The objective of the research work was to evaluate the efficiency of three different sampling methods (Ghost Wipe™, micro-vacuum, and ChemTest®) in the recovery of Be dust by assessing: (1) four Be compounds (beryllium acetate, beryllium chloride, beryllium oxide and beryllium aluminium), (2) three different surfaces (polystyrene, glass and aluminium) and (3) inter-operator variation. The three sampling methods were also tested on site in a laboratory of a dental school for validation purposes. The Ghost Wipe™ method showed recovery ranging from 43.3% to 85.8% for all four Be compounds and for all three quantities of Be spiked on Petri dishes, while recovery with the micro-vacuum method ranged from 0.1% to 12.4%. On polystyrene dishes with 0.4 µg Be, the recovery ranged from 48.3% to 81.7%, with an average recovery of 59.4% for Operator 1 and 68.4% for Operator 2. The ChemTest® wipe method with beryllium acetate, beryllium chloride, and AlBeMet® showed analogous results that are in line with the manufacturer's manual, but collection of beryllium oxide was negative. In the dental laboratory, Ghost Wipe™ samplings showed better recovery than the micro-vacuum method. The ratios between the recovered quantities of Be in each location where the Ghost Wipe™ was tested differed substantially, ranging from 1.45 to 64. In the dental laboratory, a faint blue color indicating the presence of Be was observed on the ChemTest® wipes used in two locations out of six. In summary, the Ghost Wipe™ method was more efficient than micro-vacuuming in collecting the Be dust from smooth, non-porous surfaces such as Petri dishes by a factor of approximately 18. The results obtained on site in a dental laboratory also showed better recovery with Ghost Wipes™. However, the ratio of Be recovered by Ghost Wipes™ versus micro-vacuuming was much lower for surfaces where a large amount of dust was present. Wet wiping is preferred over micro-vacuuming for beryllium forms, but this conclusion probably applies to the ultra-low particulate loading levels (0.4 micrograms or less) which was tested in this study.

Graphical abstract: Efficacy of surface sampling methods for different types of beryllium compounds

Article information

Article type
Paper
Submitted
18 Jan 2010
Accepted
20 Aug 2010
First published
28 Oct 2010

J. Environ. Monit., 2011,13, 74-83

Efficacy of surface sampling methods for different types of beryllium compounds

A. Dufresne, T. Mocanu, S. Viau, G. Perrault and C. Dion, J. Environ. Monit., 2011, 13, 74 DOI: 10.1039/C001105C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements