Issue 5, 2003

Performance optimization of isotope ratio measurements in transient signals by FI-ICP-TOFMS

Abstract

Isotopic ratios for Pb (NIST 981) and Rb (NIST 984) and their precisions measured in transient and steady state signals are presented and discussed in this work. The transient signals were generated using a flow injection system (FI) using four different loop volumes coupled to an Inductively Coupled Plasma Time-of-Flight Mass Spectrometer (ICP-TOFMS). Pneumatic nebulization (PN) with a Meinhard nebulizer or an ultrasonic nebulizer (USN) was used for sample introduction. The isotopic reference materials of Pb and Rb were dissolved and diluted to between 0.5 and 100 ng ml−1 in 4% HNO3 in Milli-Q water. Another set of mixtures was prepared with the same concentrations but fortified with 110 mg l−1 of Na. This set was introduced to produce a matrix load to the plasma in order to investigate possible effects on the isotope ratio with respect to precision and mass bias. No matrix effect on isotopic ratio and precision was observed. Analytical data for steady state signals are included for comparison to establish the best possible precision attainable on the present instrumentation given the above mentioned concentrations employing 30 s integration time and n > 5. Under those conditions, the best possible precision for isotopic ratios was 0.08% (as RSD) for 85Rb/87Rb, 0.04% for 207Pb/206Pb, 0.49% for 204Pb/206Pb and 0.07% for 208Pb/206Pb, respectively, using the analog detection mode. In transient mode the corresponding precisions were 0.2, 0.3, 1.0 and 0.3% RSD, respectively. It was found that calculation of ratio and precision performed on the whole peak profile for non-unity ratios resulted in deteriorated precision compared with calculations performed at peak apex on a minimum of five data points. As the peak intensity increases or decreases over the transient peak profile a slight change in the ratios close to the rims of the transient peak could be observed. The quality of the measurements improved for longer integration times (as long as the transient peak profile can be properly defined) and higher concentrations and with transient peak profiles that reached a steady state level. The data obtained for the two smallest loops was of poorer quality and especially for the 10 ng ml−1 solution since the analog signals obtained were rather low. For these transients results using the ion counting mode are also reported. The ion counting data obtained for concentrations ≥10 ng ml−1 and the two larger loops had, however, to be dead-time corrected. The use of USN resulted in improved precision thanks to a 10-fold increase in signal intensity.

Article information

Article type
Paper
Submitted
05 Feb 2003
Accepted
20 Mar 2003
First published
15 Apr 2003

J. Anal. At. Spectrom., 2003,18, 437-443

Performance optimization of isotope ratio measurements in transient signals by FI-ICP-TOFMS

M. Castillo Carrión, J. Reyes Andrés, J. Antonio Martín Rubí and H. Emteborg, J. Anal. At. Spectrom., 2003, 18, 437 DOI: 10.1039/B301438J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements