Jump to main content
Jump to site search
PLANNED MAINTENANCE Close the message box

Scheduled maintenance upgrade on Thursday 4th of May 2017 from 8.00am to 9.00am (BST).

During this time our websites will be offline temporarily. If you have any questions please use the feedback button on this page. We apologise for any inconvenience this might cause and thank you for your patience.


Issue 3, 2002
Previous Article Next Article

Evaluation of the NIOSH draft method 5525 for determination of the total reactive isocyanate group (TRIG) for aliphatic isocyanates in autobody repair shops

Author affiliations

Abstract

This paper evaluates the performance of the NIOSH draft method 5525 for analysis of monomeric and TRIG aliphatic isocyanates in autobody repair shops. It was found that an optimized pH gradient enhanced noticeably the resolution and, therefore, identification of aliphatic isocyanates. Samples proved to be very stable for at least a year when stored at −13 °C in the freezer, and no major stability problems were found for the MAP reagent. The detector response factor RSD for selected MAP ureas was 40% in the fluorescence (FLD), 3% in the UV at 254 nm (UV254), and 1% in the UV at 370 nm (UV370). The mean FLD/UV254 and UV254/UV370 detector response ratios of standards were 31.7 (RSD = 37.8) and 17.1 (RSD = 5.4), respectively. The FLD/UV254 ratio in bulks varied from 0.41 to 1.97 times the HDI monomer ratio. The mean UV254/UV370 ratio in bulks was 16.1 (range 14.1 to 19.2, N = 38). Mean (range) recovery of 92 (91.2–93.2)% was found for the N3300 (isocyanurate) spiked on 25 mm quartz fiber filters in the range 0.07 to 2.2 µg NCO ml−1. Mean (range) recovery for impingers was 100.7 (91.7–106.0)% for N3300 in the concentration range of 0.018 to 2.5 µg NCO ml−1 and 81.0 (76.1–89.1)% for IPDI in the concentration range of 0.016 to 1.87 µg NCO ml−1. Analytical method precision was 3.4% and mean bias 7.4% (range = 0–25%). The NIOSH draft method 5525 provides flexibility, enhanced sensitivity and specificity, powerful resolution, and very small compound-to-compound variability in the UV254, resulting in a more reliable identification and quantification of aliphatic isocyanates.

Back to tab navigation
Please wait while Download options loads

Supplementary files

Publication details

The article was received on 19 Nov 2001, accepted on 26 Mar 2002 and first published on 26 Apr 2002


Article type: Paper
DOI: 10.1039/B110613A
Citation: J. Environ. Monit., 2002,4, 351-360
  •   Request permissions

    Evaluation of the NIOSH draft method 5525 for determination of the total reactive isocyanate group (TRIG) for aliphatic isocyanates in autobody repair shops

    D. Bello, R. P. Streicher and S. R. Woskie, J. Environ. Monit., 2002, 4, 351
    DOI: 10.1039/B110613A

Search articles by author