Issue 9, 1995

Quantitative analysis of copper alloys by laser-produced plasma spectrometry

Abstract

Laser-produced plasma spectrometry was applied to the determination of low iron, nickel and silver concentrations in copper alloys. A focused Nd: YAG laser beam was used to generate a plasma from copper targets in air at atmospheric pressure. The plasma temperature was obtained by using a Boltzmann plot of neutral iron lines. Calibration curves for iron, nickel and silver were produced. The precision ranged from 2 to 10% of the analyte concentration. The detection limits were 20, 10 and 1 µg g–1 for iron, nickel and silver, respectively.

Article information

Article type
Paper

J. Anal. At. Spectrom., 1995,10, 643-647

Quantitative analysis of copper alloys by laser-produced plasma spectrometry

M. Sabsabi and P. Cielo, J. Anal. At. Spectrom., 1995, 10, 643 DOI: 10.1039/JA9951000643

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.