Abstract

This study explored the influence of structural characteristics of organic contaminants on the degradation during an advanced oxidation process (AOP). The target contaminants were acetaminophen (ACT), bisphenol A (BPA), and tetracycline (TC). The Fenton process was selected as the model process in which major reactive species of hydroxyl radicals in most AOPs are generated for target compound degradation. The optimal reagent concentration ratio was [Fe2+]/[H2O2] = 0.5 mM/0.5 mM in an acidic condition, resulting in 83.49%, 79.01%, and 91.37% removals of ACT, BPA, and TC, respectively. Contrarily, the mineralization rates were apparently lower compared to their respective removal efficiencies. Experimental observation also suggested that the aromatic structure was rather difficult to degrade since their unsaturated electron clouds would hinder the attack of hydroxyl radicals due to electric repulsion. The preferred attacking sites of an aromatic ring differ due to the functional groups and structure symmetry. However, the electrophilic attack of the hydroxyl radical is the major reaction for decomposing aliphatic structures of cyclic or branched organics, resulting in the highest removal and mineralization of TC among these three tested chemicals. In addition, an apparent removal of a contaminant may not necessarily reduce its toxic impact on the environment.


Introduction

Emerging contaminants are chemical pollutants that are “newly or not previously recognized”, “not regulated by legislation” and “risky to human health and the environment”, which include, but are not limited to, medicines, pharmaceuticals, personal care products (PPCPs), endocrine-disrupting chemicals (EDCs), and industrial additives. They are often toxic to living beings and pose adverse effects on biological metabolism, and cannot be effectively removed by conventional wastewater treatment plants.1 Some emerging contaminants have been found to function similarly to hormones that affect the immune, nervous, and endocrine systems, thus causing negative impacts (e.g., disrupting the sexual development and reproductive cycles) on organisms with prolonged exposure.2–7 It is often recommended that the types, sources, transport, and fate of emerging contaminants should be investigated to assess their impacts on the environment.8–11

Methods to remove such organic compounds from water have been explored, including adsorption, flocculation,12 chemical precipitation, microbial degradation,13,14 and AOPs.15 Among these possible treatment technologies, AOPs have gained increasing attention because of their ability to degrade most organic pollutants into smaller fractions or form carbon dioxide through mineralization.16 For example, acetaminophen (ACT), bisphenol A (BPA), and tetracycline (TC) have been treated by physical adsorption, biological oxidation, or chemical oxidation.17–20 However, the absorbed contaminants usually require further treatment to decrease their toxicity, and biological oxidation might not be as effective as expected. Against this background, AOP has been regarded as an alternative to treat emerging contaminants.

Various oxidants and catalysts have been found capable of producing radicals with strong oxidation power. Generally, the often-used radicals include the hydroxyl radical (˙OH), sulfate radical (SO4˙), and chlorine radicals (Cl˙), all of which have high redox potentials to decompose organic contaminants.2,21–23 Among them, the ˙OH is the mostly-applied oxidant24,25 that has been observed in the AOP systems containing hydrogen peroxide, persulfate, and chlorine. Besides the applied dose of the oxidants, the chemical structure of the target compound also affects the AOP effectiveness significantly. Despite the above statement, little study has been reported regarding the influence of participating molecular structure on AOP treatment efficiency.

Along this context, this study aimed to explore the influence of structural variation of target organics on the AOP degradation efficiency. The Fenton process was selected since it is the classic mechanism of ˙OH generation. The degradation experiments were carried out under acidic conditions, which is a favorable environment for the Fenton process. Three emerging contaminants ACT (a common painkiller), BPA (commonly found in plastic products), and TC (a widely-used antibiotic) were selected as the target compounds that exhibit various chemical structures of aromatic, cyclic, and aliphatic functionalities.

Materials and methods

Chemicals and reagents

Reagent-grade (99% purity or above) ACT, BPA, and TC (properties summarized in Table 1), hydrogen peroxide, phosphoric acid, sodium persulfate solution, and sodium thiosulfate were obtained from Sigma-Aldrich. Ferrous sulfate was purchased from Avantor, and methanol and oxalic acid were procured from Honeywell. Sulfuric acid (H2SO4) and phosphate buffer were used to adjust the pH, and Na2S2O3 was used to quench the Fenton reaction. Methanol and oxalic acid were employed as the mobile phase for high-performance liquid chromatography (HPLC) analysis.
Table 1 Chemical and physical properties of ACT, BPA, and TC
Chemical name Structural formula Molecular formula Molecular weight Water solubility Melting point (°C)
Acetaminophen image file: d4ra00827h-u1.tif C8H9NO2 151.16 g mole−1 12.78 g L−1 169
Bisphenol A image file: d4ra00827h-u2.tif C15H16O2 228.29 g mole−1 120 mg L−1 158
Tetracycline image file: d4ra00827h-u3.tif C22H24N2O8 444.44 g mole−1 231 mg L−1 170


Fenton experiment procedure

All the Fenton degradation experiments were conducted in a 1000 mL beaker under ambient temperature (25–30 °C). H2SO4 was added to maintain the pH at 3 for the Fenton degradation.26 The concentrations of the ferrous ions (Fe2+) and H2O2 varied from 0.1–0.5 mM at the [Fe2+]/[H2O2] ratio of 1[thin space (1/6-em)]:[thin space (1/6-em)]1 to determine the optimal dose of Fe2+ and H2O2 to achieve the highest degradation efficiency. Experiments by maintaining a constant Fe2+ concentration at 0.5 mM and varying the concentration of H2O2 (0.1, 0.3, 0.5 mM) were conducted to explore the effect of the structural variation on the degradation efficiency. An aliquot of aqueous sample was collected at 0, 0.5, 1, 2, 5, 10, 15, and 30 min after the initiation of the Fenton reaction and immediately quenched by Na2S2O3 before passing through a 0.22 μm filter. The concentrations of ACT, BPA, and TC were quantified by HPLC to calculate the degradation efficiency. The total organic carbon (TOC) of each collected sample was analyzed to determine the degree of mineralization.

Analytical methods

The HPLC employed was a Thermo Scientific Ultimate 3000 HPLC system equipped with a Thermo Scientific Acclaim 120 C18 5 μm 120 A (4.6 × 250 mm) column. The UV wavelengths at 249, 280, and 360 nm were used for detecting ACT, BPA, and TC, respectively. The column temperature was maintained at 30 °C. The injection volume of acetaminophen was 20 mL and the flow rate was 0.2 mL min−1, with a mobile phase of methanol and deionized (DI) water (methanol[thin space (1/6-em)]:[thin space (1/6-em)]DI water = 20[thin space (1/6-em)]:[thin space (1/6-em)]80). The injection volume of BPA was 20 mL and the flow rate was 0.5 mL min−1 with methanol[thin space (1/6-em)]:[thin space (1/6-em)]DI water (30[thin space (1/6-em)]:[thin space (1/6-em)]70) as the mobile phase. The injection volume of tetracycline was 20 mL and the flow rate was 1.7 mL min−1, with a mobile phase of methanol and oxalic acid (0.01 M). The gradient conditions (methanol[thin space (1/6-em)]:[thin space (1/6-em)]oxalic acid) were as follows: 15[thin space (1/6-em)]:[thin space (1/6-em)]85 at 0 min, 30[thin space (1/6-em)]:[thin space (1/6-em)]70 at 4 min, 50[thin space (1/6-em)]:[thin space (1/6-em)]50 at 5 min, 75[thin space (1/6-em)]:[thin space (1/6-em)]25 at 6 min, 50[thin space (1/6-em)]:[thin space (1/6-em)]50 at 8 min, 30[thin space (1/6-em)]:[thin space (1/6-em)]70 at 9 min, and 15[thin space (1/6-em)]:[thin space (1/6-em)]85 at 11 min. Total organic carbon (TOC) analysis was performed using a TOC analyzer (TOC-OIA_1030W) which employed a low-temperature wet oxidation method. An acidifier (5% phosphoric acid solution) was added to remove the inorganic carbon and the oxidizer (100 g L−1 sodium persulfate solution) was introduced at 100 °C to oxidize the organic matter into CO2 which was transferred into a non-dispersive infrared analyzer that can absorb a specific wavelength by the carrier gas (oxygen).

Risk analysis methodology

The toxicity of ACT, BPA, TC, and their possible degradation products were predicted using ECOSAR (Ecological Structure Activity Relationship Class Program) which is one of the modules in EPI (Estimation Programs Interface) Suite™ (version 4.11) released by the US Environmental Protection Agency (EPA). The ECOSAR estimates the acute and chronic toxicity to aquatic organisms, including fish, invertebrates, and green algae. In this study, the median lethal concentration (LC50) was estimated by ECOSAR to compare the toxicity between the parent compound and its degradation products, assessing the ecological risk during the degradation of each parent compound.

Theoretical assessment of potential reactive sites by Fukui function

The Fukui function is useful to predict the electrophilic, nucleophilic, and free radical attack sites in a compound, which is defined as:
 
image file: d4ra00827h-t1.tif(1)
where ρ([r with combining right harpoon above (vector)]) is the electron density at point r in space, N is the number of electrons, and v is the external potential. In the condensed Fukui function (CFF), the reactive sites have larger values than other regions, which makes the potential preferred reaction sites predictable. Three types of condensed Fukui indices, which are f+, f, and f0, represent nucleophilic attack, electrophilic attack, and radical attack, respectively. The calculation of reactions:
 
Nucleophilic attack: f+ = [qi(N + 1) − qi(N)] (2)
 
Electrophilic attack: f = [qi(N) − qi(N − 1)] (3)
 
image file: d4ra00827h-t2.tif(4)
where qi is the atomic charge.

Density functional theory (DFT) calculations for the Fukui function were carried out by Gaussian 09 program software. For ACT and BPA, 6-31G(d,p) and B3LYP (Becke's three parameters and Lee–Yang–Parr functional) were utilized as a basis set. For TC, 6-311+g(d,p) and functional M06-2X-D3 were the basis sets used for C, H, O, and N. Multiwfn software was used to calculate and visualize the condensed Fukui indices.

Results and discussion

The degradation by hydroxyl radicals

The degradation efficiencies of ACT, BPA, and TC at the 1[thin space (1/6-em)]:[thin space (1/6-em)]1 ratio of [H2O2][thin space (1/6-em)]:[thin space (1/6-em)][ Fe2+] are presented in Fig. 1, showing that the degradation occurred rapidly within 5 to 10 minutes and remained stable thereafter as the H2O2 concentration increased from 0.1 mM to 0.5 mM. The maximum removal of ACT, BPA, and TC was 83.49%, 79.01%, and 91.37%, respectively, with 0.5 mM Fe2+/0.5 mM H2O2, consistent with the findings in the literature.27–29 With the same oxidant/catalyst dose application, different removal rates were observed, implying that the molecular structure should be a factor that affects the compound degradation. In the experiment with 0.1 mM applied reagent doses, TC showed the highest removal (76.95%) rate among the three investigated chemicals.
image file: d4ra00827h-f1.tif
Fig. 1 The degradation of the ACT (A), BPA (B), and TC (C) by the hydroxyl radical at different concentrations of [Fe2+][thin space (1/6-em)]:[thin space (1/6-em)][H2O2] with the ratio of 1[thin space (1/6-em)]:[thin space (1/6-em)]1. The degradation curves are simulated by first-order kinetics.

Structurally speaking, BPA consists of two aromatic rings, ACT consists of one aromatic ring, and TC consists of one aromatic ring along with three additional cyclic rings. Molecular structures with higher aromaticity decreased the removal efficiency in an AOP. The aromatic ring is a resonance structure that is more stable than the saturated and unsaturated covalent bonds of the cyclic structure (as present in TC) and difficult to degrade. It has also been suggested that the AOP degradation efficiency would be reduced with the increase in ring functional groups.30

The degradation curve of emerging contaminants by ˙OH could be described by the first-order kinetic model (eqn (5)),31 where C0 and Cequil are the initial and equilibrium concentrations of the target compound, and k is the rate constant in minutes.

 
C = (C0Cequil) × ekt + Cequil (5)

The kinetic parameters are summarized in Table 2. The reaction between H2O2 and Fe2+ produces ˙OH that achieves an obvious removal of the target contaminants. The degradation efficiency by ˙OH was positively correlated to the Fe2+ and H2O2 concentrations. However, the degradation rate is not proportional to the applied reagent concentrations, because of the complicated reacting mechanism in the Fenton process.

Table 2 Kinetic parameters for Fenton oxidation of ACT, BPA, and TC at different concentrations of [Fe2+][thin space (1/6-em)]:[thin space (1/6-em)][H2O2] and maintaining a ratio of 1[thin space (1/6-em)]:[thin space (1/6-em)]1a
Compound Reagent concentration (mM) C0 Cequil k (min−1) R2
a C0 is the initial concentration of the target compound at 0 min; Cequil is the target compound concentration when achieving Fenton equilibrium; k is the first-order kinetic rate constant; R2 indicates the goodness of kinetic model fitting.
ACT 0.1 48.95 35.26 0.2669 0.9877
0.2 48.81 26.17 0.4313 0.9831
0.3 49.58 18.82 1.1000 0.9946
0.4 50.38 14.07 1.2810 0.9929
0.5 49.87 8.42 2.4640 0.9977
BPA 0.1 49.71 34.60 0.1731 0.9976
0.2 49.14 32.74 0.5673 0.9849
0.3 49.01 25.21 0.8062 0.9853
0.4 49.10 16.82 0.9897 0.9907
0.5 50.05 10.46 2.3610 0.9997
TC 0.1 49.98 11.41 3.3110 0.9994
0.2 50.00 8.89 3.4970 0.9998
0.3 50.00 8.12 3.7160 0.9998
0.4 50.00 6.21 7.6310 0.9980
0.5 50.00 4.80 6.5000 0.9978


The decomposition effect of various oxidant concentrations

The result of using 0.5 mM Fe2+ concentration (i.e., catalyst in the process) and varying H2O2 concentrations (i.e., 0.1, 0.3, and 0.5 mM as the oxidant) are shown in Fig. 2A, C and E, indicating that the degradation was enhanced with increasing H2O2 concentration, with TC being the most-degraded and BPA the least-degraded target compounds. The degradation is regressed by a first-order kinetic model and the kinetics parameters are shown in Table S1.
image file: d4ra00827h-f2.tif
Fig. 2 The degradation (A), (C) and (E) and mineralization (B), (D) and (F) of the different contaminants at ferrous ion concentration of 0.5 mM and varying concentrations of H2O2. The degradation curves are simulated by first-order kinetics.

The TOC content was measured for mineralization assessment and the results are shown in Fig. 2B, D and F. For the investigated contaminants, the mineralization was improved as the H2O2 concentration increased from 0.1 to 0.5 mM. The TC was found to have higher mineralization rates compared to ACT and BPA. Overall, the mineralization rates remained relatively low compared to the removal rates.

In an ˙OH-driven AOP, the target compound decomposes to form intermediates/fractions, which may become scavengers or competitive organics of available ˙OH.32,33 Therefore, the unreacted contaminants and resulting intermediates/fractions would compete for ˙OH to achieve further decomposition. In the present study, the parent contaminant remains rather difficult to decompose because of the aromatic structure, as opposed to the resulting intermediates and fragmented molecules. Also, the amount of parent contaminants was outnumbered by that of the resulting intermediates after the initiation of the degradation process. From the classical collision theory of chemical reactions and considering the aromaticity of tested parent compounds, the ˙OH would react with intermediates preferably, and no apparent increase in contaminant removal was observed.

From the above statements, the apparent removal of tested contaminants suggested that their molecular structures have been altered, either by bond-breaking in the aliphatic and branched structures or by aromatic ring cleavage. The un-decomposed parent compounds and the resulting organic fractions remain in existence during the degradation, supporting the observation that the degree of mineralization might be quite limited. Since ˙OH is highly active and could be consumed rapidly as the bond-breaking process proceeds in the degradation, much more hydroxyl radicals (i.e., more H2O2) are required to oxidize the existing target compounds and intermediate organics to increase the mineralization rate in the present study.

The toxicity variation evaluation in the degradation process using ECOSAR

Generally, water pollution control practice aims to remove aqueous pollutants through treatment processes and the efficiency is determined by the concentration difference of the target pollutant between influent and effluent wastewaters. While the issues of public and environmental health attract increasing attention, the potential threats from all the existing organics should be considered. In light of this concept, this study also evaluated the toxicity variation of a given target compound considering the toxic impact from the parent compound and its daughter intermediates during the degradation process. The pollutants' toxicities were assessed using the ECOSAR of EPI Suite software and the degradation pathways of ACT,34 BPA,20 and TC35 were adopted from the literature. The structural parameters of the parent contaminants and the resulting intermediates were introduced into the EPI Suite and their 50% lethal concentrations (LC50) were simulated using ECOSAR to establish the baseline toxicities of the target contaminants to fish (Fig. 3).
image file: d4ra00827h-f3.tif
Fig. 3 The main toxicity variation and degradation pathway20,34,35 of (A) ACT, (B) BPA, and (C) TC during the degradation process.

As shown in Fig. 3A, the resulting intermediates (other than organic acids and ammonium ion) during the degradation were found more toxic than ACT, implying that the overall chemical toxicity during AOP might increase if ultimate mineralization is not achieved. Theoretically, the intermediates may continue to oxidize, forming the end products of CO2 and H2O if enough ˙OH are present. However, no reported studies have shown the full spectrum of possible oxidation by-products before mineralization for the investigated contaminants. Similar to the degradation of ACT, according to the pathway shown in Fig. 3C, all the proposed intermediates were considered more toxic than TC. Therefore, it is suggested that complete mineralization would be deemed appropriate if ACT or TC is treated with AOPs.

In contrast, the lethal concentrations of the observed intermediates (as shown in Fig. 3B) from BPA degradation increased, showing less toxicity of the resulting intermediates. In field practice, using AOPs to treat BPA seems to be a feasible alternative since the formation of intermediates would not increase the overall toxicity while complete mineralization is hardly achieved.

Based on a common perception of oxidation capability, AOPs were often used to treat recalcitrant organic contaminants since the oxidative radicals are highly reactive almost without selectivity. However, mineralization rates by AOPs are usually low, since complete breakage of all the organic bonds requires massive amounts of oxidants (i.e., generated radicals in an AOP). The findings from the study showed that the existence of remaining intermediates may pose even higher threats to the ecology and environment. Therefore, a further evaluation of the suitability of the AOP application (i.e., ecological risk analysis in addition to general treatment efficiency) should be conducted before its on-site practice.

Effect of the molecular structure on degradation by ˙OH

Among the three investigated chemicals, both ACT and BPA have a relatively simple structure (as shown in Table 1), and the number of aromatic rings in the structure affects the degradation rates. On the other hand, TC has one aromatic ring attached by three cyclic structures and branches and ˙OH would attack the single-bonded structures preferentially.

In AOPs, decomposition by oxidants such as hydroxyl radicals, sulfate radicals, and superoxide radicals are the dominant oxidation pathways.36 From the perspective of molecular structure, the radicals prefer to attack the highest occupied molecular orbital (HOMO) site on the target compound, which makes the radical-attacked preferred sites predictable. The Fukui index representing electrophilic attack (f) and radical attack (f0) are considered based on the density functional theory (DFT).37–39 Considering the primary reactive radical (i.e., ˙OH) in the present study, the calculations of the Fukui index and the values were adopted from the literature and summarized in Tables S2–S4 and the possible reactive sites with ˙OH were shown in Fig. 4.36,40–42


image file: d4ra00827h-f4.tif
Fig. 4 The possible reactive sites with ˙OH predicted by Fukui index (f and f0). (A) ACT, (B) BPA, and (C) TC.

For ACT containing a single benzene ring, the radicals prefer to attack the para-position of the benzene ring, opposite to the phenol group (i.e., C6 position in Fig. 4A), and release hydroquinone and acetamide as degradation byproducts36 (Fig. 3A). A similar radical attack on para-position was also shown at the formation of p-hydroquinone from phenol in the BPA degradation pathway (Fig. 3B). Different from ACT, BPA encompasses two benzene rings in a symmetrical structure, resulting in a barrier for ˙OH attack on the para-position of the phenol group. Instead, ˙OH is suggested to attack the ortho-position (i.e., C1, C3, C12, C14 positions in Fig. 4B) of the phenol group of the benzene ring through hydroxylation.41,42 Furthermore, phenol and 4-isopropenylphenol were formed via the β-scission (i.e., cleavage of C–C bond) by the attack of ˙OH at C7 position (Fig. 3B).20 In TC, both the most preferred radical and electrophilic attack site (highest f0 and f value) is N19 position, forming a C–OH bond on C12. Subsequently, the C9–C12 covalent bond of the intermediate was broken by ˙OH attack, resulting in the cyclic cleavage of the IV ring (Fig. 3C).40,43

Compared to ACT and BPA, TC consists of both benzene and cyclic rings in its molecular structure and the ˙OH tends to degrade the non-aromatic part (e.g. side branches and cyclic ring) of TC first, thus explaining the highest overall degradation among the three target compounds. The highest f0 value of TC appears at the side amine branch on the non-aromatic ring (i.e., N19 position), leading to the fast first-step degradation of parent compounds. Moreover, TC has a larger molecular size than ACT and BPA which increases the opportunity for collision reactions with free radicals, showing the highest apparent degradation rate (i.e., the highest k value in Table S1). For the actual degradation in the whole system including the intermediates, the Fukui function calculation can be applied to each intermediate to predict the preferred sites. The stable degradation was observed after 10 minutes because of the generated molecular fractions from parent contaminants by ˙OH reactions (Fig. 1 and 2).

Conclusions

In summary, this study explored the impact of molecular structure on the degradation efficiency by AOP and the overall toxicity in the degradation was assessed. The best operation condition occurred at 0.5 mM Fe2+ and 0.5 mM H2O2, resulting in the best removal rates of 83.49% for ACT, 79.01% for BPA, and 91.37% for TC in an acidic condition. Despite the occurrence of apparent removal, the mineralization rates were still low, implying the possible roles of reaction intermediates as the radical scavengers at the end of the AOP degradation. Also, the number of aromatic rings in the reactant is a critical factor impacting the degradation efficiency since the unsaturated aromatic electron clouds would hinder the possible attack by the ˙OH. On the contrary, non-aromatic branched structures would exhibit more vulnerability to the attack by ˙OH, resulting in a higher observed degradation efficiency. Among the three tested compounds, the most radical-attack preferred site with the highest f0 value of TC is the side amine branch on the non-aromatic ring, causing the easiest decomposition of TC by hydroxyl radicals and showing the most obviously apparent degradation result. In addition, an apparent removal of a contaminant may not necessarily reduce its toxic impact on the environment. The reaction intermediates may possess higher toxicity than their parent compounds, implying that the AOP application may induce a higher overall toxicity to the ecology and environment.

Conflicts of interest

The authors declare no competing financial interest.

Acknowledgements

This work is partially supported by the National Science and Technology Council, Taiwan under the grant numbers of NSTC 108-2313-B-002-026 and 109-2313-B-002-049-MY2.

References

  1. L. Mandaric, M. Celic, R. Marcé and M. Petrovic, in Emerging Contaminants in River Ecosystems, Springer, 2015, pp. 3–25 Search PubMed.
  2. M. Adeel, X. Song, Y. Wang, D. Francis and Y. Yang, Environ. Int., 2017, 99, 107–119 CrossRef CAS PubMed.
  3. L. Ma and S. R. Yates, Sci. Total Environ., 2018, 640, 529–542 CrossRef PubMed.
  4. W. B. Whitman, Cell Chem. Biol., 2017, 24, 652–653 CrossRef CAS PubMed.
  5. R. Baccar, M. Sarrà, J. Bouzid, M. Feki and P. Blánquez, Chem. Eng. J., 2012, 211–212, 310–317 CrossRef CAS.
  6. E. J. Marti and J. R. Batista, Sci. Total Environ., 2014, 470, 1056–1067 CrossRef PubMed.
  7. S. Sauvé and M. Desrosiers, Chem. Cent. J., 2014, 8, 15 CrossRef PubMed.
  8. R. M. Clarke and E. Cummins, Hum. Ecol. Risk Assess., 2015, 21, 492–513 CrossRef CAS.
  9. M. Grassi, G. Kaykioglu, V. Belgiorno and G. Lofrano, in Emerging Compounds Removal from Wastewater, Springer, 2012, pp. 15–37 Search PubMed.
  10. S. Smith, Philos. Trans. R. Soc., A, 2009, 367, 4005–4041 CrossRef CAS PubMed.
  11. J. Wilkinson, P. S. Hooda, J. Barker, S. Barton and J. Swinden, Environ. Pollut., 2017, 231, 954–970 CrossRef CAS PubMed.
  12. C. S. Lee, J. Robinson and M. F. Chong, Process Saf. Environ. Prot., 2014, 92, 489–508 CrossRef CAS.
  13. J. Liu and S. Mejia Avendaño, Environ. Int., 2013, 61, 98–114 CrossRef CAS PubMed.
  14. M. Sudha, A. Saranya, G. Selvakumar and N. Sivakumar, Int. J. Curr. Microbiol. Appl. Sci., 2014, 3, 670–690 CAS.
  15. X. Hu, B. Liu, Y. Deng, H. Chen, S. Luo, C. Sun, P. Yang and S. Yang, Appl. Catal., B, 2011, 107, 274–283 CrossRef CAS.
  16. A. Stasinakis, Global NEST J., 2008, 10, 376–385 Search PubMed.
  17. H. Katsumata, S. Kawabe, S. Kaneco, T. Suzuki and K. Ohta, J. Photochem. Photobiol., A, 2004, 162, 297–305 CrossRef CAS.
  18. M. Umar, F. Roddick, L. Fan and H. A. Aziz, Chemosphere, 2013, 90, 2197–2207 CrossRef CAS PubMed.
  19. L. Xu, H. Zhang, P. Xiong, Q. Zhu, C. Liao and G. Jiang, Sci. Total Environ., 2020, 141975 Search PubMed.
  20. X. Zhang, Y. Ding, H. Tang, X. Han, L. Zhu and N. Wang, Chem. Eng. J., 2014, 236, 251–262 CrossRef CAS.
  21. A. Boscolo Boscoletto, F. Gottardi, L. Milan, P. Pannocchia, V. Tartari, M. Tavan, R. Amadelli, A. De Battisti, A. Barbieri, D. Patracchini and G. Battaglin, J. Appl. Electrochem., 1994, 24, 1052–1058 CrossRef.
  22. C. Casado, J. Moreno-SanSegundo, I. De la Obra, B. Esteban García, J. A. Sánchez Pérez and J. Marugán, Chem. Eng. J., 2021, 403, 126335 CrossRef CAS.
  23. Y. Deng and R. Zhao, Curr. Pollut. Rep., 2015, 1, 167–176 CrossRef CAS.
  24. C. Fan, L. Tsui and M.-C. Liao, Chemosphere, 2011, 82, 229–236 CrossRef CAS PubMed.
  25. N. Klamerth, S. Malato, M. Maldonado, A. Aguera and A. Fernández-Alba, Environ. Sci. Technol., 2010, 44, 1792–1798 CrossRef CAS PubMed.
  26. Y. S. Jung, W. T. Lim, J. Y. Park and Y. H. Kim, Environ. Technol., 2009, 30, 183–190 CrossRef CAS PubMed.
  27. W. Chen, C. Zou, Y. Liu and X. Li, J. Ind. Eng. Chem., 2017, 56, 428–434 CrossRef CAS.
  28. M. D. G. de Luna, M. L. Veciana, J. I. Colades, C.-C. Su and M.-C. Lu, J. Taiwan Inst. Chem. Eng., 2014, 45, 565–570 CrossRef CAS.
  29. M. H. Mahdi, T. J. Mohammed and J. A. Al-Najar, Eng. Technol. J., 2021, 39, 260–267 CrossRef.
  30. M. A. Engwall, J. J. Pignatello and D. Grasso, Water Res., 1999, 33, 1151–1158 CrossRef CAS.
  31. D. Bhangare, N. Rajput, T. Jadav, A. K. Sahu, R. K. Tekade and P. Sengupta, J. Anal. Sci. Technol., 2022, 13, 7 CrossRef.
  32. S. Gligorovski, R. Strekowski, S. Barbati and D. Vione, Chem. Rev., 2015, 115, 13051–13092 CrossRef CAS PubMed.
  33. Y.-Y. Lee and C. Fan, Chemosphere, 2020, 258, 127338 CrossRef CAS PubMed.
  34. M. D. G. de Luna, M. L. Veciana, C.-C. Su and M.-C. Lu, J. Hazard. Mater., 2012, 217, 200–207 CrossRef PubMed.
  35. Z. Zhu, X. Tang, S. Kang, P. Huo, M. Song, W. Shi, Z. Lu and Y. Yan, J. Phys. Chem. C, 2016, 120, 27250–27258 CrossRef CAS.
  36. M. Qutob, M. A. Hussein, K. A. Alamry and M. Rafatullah, RSC Adv., 2022, 12, 18373–18396 RSC.
  37. F. De Vleeschouwer, V. Van Speybroeck, M. Waroquier, P. Geerlings and F. De Proft, Org. Lett., 2007, 9, 2721–2724 CrossRef CAS PubMed.
  38. R. G. Parr and W. Yang, J. Am. Chem. Soc., 1984, 106, 4049–4050 CrossRef CAS.
  39. P. P. Zamora, K. Bieger, A. Cuchillo, A. Tello and J. P. Muena, J. Mol. Struct., 2021, 1227, 129369 CrossRef CAS.
  40. C. Fang, S. Wang, H. Xu and Q. Huang, Sci. Total Environ., 2022, 812, 152455 CrossRef CAS PubMed.
  41. J. Lee, S. Eom, S. Sohn, T. Kim and K.-D. Zoh, Chem. Eng. J., 2023, 470, 144041 CrossRef CAS.
  42. D. Wang, J. Liang, H. Zhang and J. Zhang, ACS ES&T Water, 2022, 2, 156–164 Search PubMed.
  43. B. Yang, X. Cheng, Y. Zhang, W. Li, J. Wang and H. Guo, Environ. Sci. Ecotechnology, 2021, 8, 100127 CrossRef CAS PubMed.

Footnote

Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d4ra00827h