Minxian
Wu
a,
Gijs
Vanhoutte
a,
Neil R.
Brooks
b,
Koen
Binnemans
b and
Jan
Fransaer
*a
aDepartment of Materials Engineering, KU Leuven, Kasteelpark Arenberg 44 – bus 2450, B-3001 Leuven, Belgium. E-mail: jan.fransaer@mtm.kuleuven.be; Fax: +32 16 32 19 91; Tel: +32 16 32 12 60
bDepartment of Chemistry, KU Leuven, Celestijnenlaan 200F – bus 2404, B-3001 Leuven, Belgium
First published on 10th April 2015
The electrodeposition of germanium at elevated temperatures up to 180 °C and pressures was studied from the ionic liquids 1-butyl-1-methylpyrrolidinium dicyanamide and 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide containing [GeCl4(BuIm)2] (where BuIm = 1-butylimidazole) or GeCl4. Cyclic voltammetry (CV), electrochemical quartz crystal microbalance (EQCM), rotating ring-disk electrode (RRDE), scanning electron microscope (SEM), X-ray diffraction (XRD), transmission electron microscopy (TEM), electron backscatter diffraction (EBSD) and Auger electron spectroscopy (AES) were used to investigate the electrochemical behavior and the properties of the electrodeposited germanium. Electrodeposition at elevated temperatures leads to higher deposition rates due to: (1) increase in the diffusion rate of the electroactive germanium compounds; (2) faster electrochemical kinetics in the electrolyte; and (3) higher electrical conductivity of the electrodeposited germanium film. Moreover, the morphology of the germanium film is also of a better quality at higher electrodeposition temperatures due to an increase in adatom mobility.
Ionic liquids are solvents that consist entirely of ions. They have a wide electrochemical window and an intrinsic ionic conductivity.12,13 Using ionic liquids as electrolytes and performing electrodeposition from ionic liquids has been a hot research topic during last decade. Some metals that are impossible to deposit from water due to hydrolysis or due to the fact that hydrogen evolution happens before metal ion reduction can be electrodeposited from ionic liquids because water can be easily removed.14 Endres and coworkers first reported on germanium electrodeposition from the ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate using germanium(IV) halides as germanium source.15–18 Germanium nanoclusters were obtained, but carbon, oxygen and halogen impurities were detected in the deposits. Germanium has also been electrodeposited from other ionic liquids, e.g. 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide, 1-ethyl-2,3-dimethylimidazolium bis(trifluoromethylsulfonyl)imide.19–21 Due to the low boiling point of GeCl4 (86.5 °C), most of the depositions have been carried out at room temperature. Xin et al. performed SixGe1−x deposition from 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide using GeCl4 and SiCl4 at 90 °C and found a 2D-ordered SixGe1−x deposit at 90 °C instead of the 3D structure that was formed at room temperature.22 The film morphology was improved due to the increase of adatom mobility on the surface at elevated temperatures.23 To prevent the evaporation of the electroactive germanium compound, we used a new germanium compound [GeCl4(BuIm)2] (where BuIm = 1-butylimidazole), which is much less volatile than GeCl4, and successfully electrodeposited porous germanium films from a mixture of 1-butyl-1-methylpyrrolidinium dicyanamide and 1-butyl-1-methylpyrrolidinium chloride at 100 °C.24 The deposition rate at 100 °C was much higher than at room temperature. Because at elevated temperatures, both the diffusion rate of germanium ions and electrochemical kinetics are increased. Also, the electrical conductivity (σ) of electrodeposited germanium film also increased at higher temperatures as σ ∝ exp(−Eg/2kBT), where Eg is the band gap of the material, kB is the Boltzmann constant, and T is the absolute temperature.25
This paper is about the electrodeposition of germanium at elevated temperatures up to 120 °C from 1-butyl-1-methylpyrrolidinium dicyanamide and up to 180 °C from 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide. To prevent the evaporation of [GeCl4(BuIm)2] and GeCl4, a high pressure electrochemical cell was built. At temperatures higher than 150 °C, dense shiny germanium films could be electrodeposited and high deposition rates could be obtained.
The electrolyte solutions were prepared in an argon-filled glove box (oxygen and water contents were below 1 ppm), and then the electrolytes were transferred into a closed pressure cell. The schematic drawing of the pressure electrochemical cell is shown in Fig. 1. It was a cylindrical glass cell with a screw cap. The electrochemical experiments were performed outside the glove box and the closed cell was entirely immersed in a hot silicon oil bath. All the electrochemical experiments were carried out in a three-electrode system. The counter electrode was a p-type germanium wafer and a platinum wire was used as a pseudo-reference electrode. The working electrode used for cyclic voltammetry and for linear scan voltammetry experiments was a polished platinum disk (ϕ = 1 mm) embedded in EpoFix® resin. In rotating ring-disk electrode experiments, a platinum/platinum rotating ring-disk electrode (Pine Research Instrumentation, E7R8 Series) was used as working electrode. The dimensions of the ring and disk electrodes were provided by the supplier. The disk has a diameter of 4.57 mm (2r1), and the inside and outside diameters of the ring are 4.93 mm (2r2) and 5.38 mm (2r3), respectively. Platinum-coated silicon wafers (silicon covered with 500 nm of silica, 10 nm of titanium and 100 nm of platinum) or n-type germanium wafers (Umicore, Cz88 742) were used as working electrode for germanium deposition. Before electrodeposition, all the substrates were rinsed with deionized water and absolute ethanol and finally dried in a stream of hot air. An EG & G 273 potentiostat or an Autolab 302N was used for electrochemical experiments.
![]() | ||
Fig. 1 Schematic drawing of the electrochemcial cell used for electrochemical experiments at elevated temperatures. |
The electrochemistry of germanium deposition in [BMP][Tf2N] was studied by electrochemical quartz crystal microbalance (EQCM, Maxtek RS232/IEEE488). The mass change per unit area (Δm) on a platinum-coated 5 MHz quartz crystal was determined by the Sauerbrey equation:
Δf = −CfΔm | (1) |
The concentration of [BMP][Tf2N] containing GeCl4 was determined using inductively coupled plasma optical emission spectroscopy (ICP-OES, Varian 720-ES apparatus). Because [BMP][Tf2N] is immiscible with water, methanol was added to make the ICP solutions. The morphology and elemental composition of the films were determined by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX, Philips XL 30 FEG). X-ray diffraction (XRD, Seifert 3003), transmission electron microscopy (TEM, FEI Tecnai G2 F20) and electron backscatter diffraction (EBSD) were used to characterize the crystal structure of the deposits. TEM sample was prepared with focused ion beam (FIB, FEI Helios). EBSD was performed using a TSL-EDAX system on an FEI Nova 600 NanoLab instrument. The cross-sections for EBSD measurement and SEM were prepared using a JEOL cross-section polisher.
Auger electron spectroscopy (AES) was used for analyzing the carbon impurity in the germanium film. The Auger chamber (Thermo Scientific) was under ultrahigh vacuum (8.9 × 10−9 Torr) and spectra were measured using a primary electron beam with an energy of 8 keV with a typical current of 10 nA and a Gaussian profile with a radius of about 0.5 mm. Auger electrons were detected with a hemispherical analyzer (Thermo Scientific) in an energy range from 100 eV up to 1500 eV. Depth profiling was done by sputtering with an argon ion beam for 5 min between each AES measurement. The sputter beam current was approximately 3 μA, and the beam size had a Gaussian profile with a diameter of approximately 1 mm and was scanned over an area of 2 × 2 mm2. AES spectra was analyzed using Avantage Data System software (Thermo Scientific).
![]() | ||
Fig. 2 Color changes of pure [BMP][DCA] after heating at 140 °C for different times: (a) 0 h, (b) 20 h, and (c) 72 h. |
![]() | (2) |
![]() | ||
Fig. 3 Vapor pressure of GeCl4 as a function of temperature. The black line was calculated based on eqn (2) and the circles are the experimental data from the literature.31 |
The viscosity and density of [BMP][Tf2N] change with temperature. The density of [BMP][Tf2N] at different temperatures was described in the literature.32,33 The kinematic viscosity (ν) of pure [BMP][Tf2N] was measured at different temperatures and was converted to dynamic viscosity (Fig. 4). The viscosity non-linearly decreases with increasing temperatures. This nonlinear effect can be described by the Tammann–Vogel–Fulcher (TVF) equation:
log![]() ![]() | (3) |
![]() | ||
Fig. 4 Tammann–Vogel–Fulcher fitting of viscosity change of ionic liquid [BMP][Tf2N] with temperature. |
Fig. 5a shows the cyclic voltammograms of 0.5 M GeCl4 in [BMP][Tf2N] at room temperature. The cyclic voltammograms were stopped at cathodic vertex potentials of −1.0 V, −1.2 V, −1.5 V, −1.7 V, −2.0 V and −2.5 V to study the reactions happening at different potentials. There are two reduction peaks on the cathodic scan and three oxidation waves on the anodic scan. The second oxidation peak a2 correlated to the first reduction peak r1 at −1.1 V. The peak current density of a2 increased as more negative cathodic vertex potential was applied. The first reduction peak r1 is due to the reduction of Ge(IV) to Ge(II). This was further proven using potential scan experiment: a constant potential of −1.0 V was applied until the charge density reached 2 C dm−2. Ge(II) ions were formed at the working electrode. Then the potential was scanned from −1.0 V to +1.5 V after waiting at open circuit potential for different times (0 s, 10 s, 30 s and 300 s). With longer waiting time, more Ge(II) ions diffused away from working electrode. The oxidation peak a2 which was due to the oxidation of Ge(II) to Ge(IV) decreased as longer waiting times were applied (see ESI†). When an even more negative cathodic vertex potential was applied, the second oxidation peak a2 decreased, less Ge(II) was in the solution because at the second reduction peak r2 Ge(II) was further reduced to Ge(0). The oxidation peak a3 corresponds to the oxidation of chloride ions to chlorine gas (vs. SHE). Chloride ions are present in solution after reduction of GeCl4 to Ge(0). The oxidation potential of chloride ions was determined using a [BMP][Tf2N] solution containing 0.4 M [BMP]Cl. Fig. 6 shows the linear sweep voltammograms of 0.4 M [BMP]Cl in [BMP][Tf2N]. An oxidation peak could be observed at +1.07 V which was due to the oxidation of chloride ions to chlorine gas. This peak is not present in pure [BMP][Tf2N]. The first oxidation peak a1 appeared only when the cathodic potential was scanned to the second reduction peak r2, indicating a1 was due to the stripping of Ge(0).
When the cell was immersed in the heating bath to 150 °C some gas bubbles were formed in the solution due to the high volatility of the GeCl4. The formation of gas bubbles stopped when the final temperature was reached. The cyclic voltammogram of 0.5 M GeCl4 in [BMP][Tf2N] at 150 °C is quite similar to the cyclic voltammogram at room temperature (Fig. 5b). There are two reduction peaks on the cathodic scan. The first one at −1.25 V is due to the reduction of Ge(IV) to Ge(II), and the second reduction peak at −2.1 V corresponds to the deposition of Ge(0). The peak current density is −4.2 A dm−2 compared to −1.3 A dm−2 at room temperature. The increase in the current density is due to the reduction of the viscosity at elevated temperatures. The decrease in viscosity leads to an increase in diffusion coefficient of Ge(IV) ions in [BMP][Tf2N]. The diffusion coefficient of Ge(IV) was calculated based on the following equations:35
![]() | (4) |
![]() | (5) |
![]() | (6) |
The electrochemical behavior of [BMP][Tf2N] solution containing GeCl4 was further studied using electrochemical quartz crystal microbalance (EQCM). As shown in Fig. 8a, a cyclic voltammogram was recorded on a platinum-coated EQCM crystal working electrode, and the corresponding frequency change was simultaneously recorded by EQCM. Based on the frequency change, the mass change on the crystal was calculated from the Sauerbrey equation. The m/z value was calculated at different potential ranges (Fig. 8b) and it varies for different reactions:
Ge4+ + 2e− → Ge2+ m/z = 0 | (7) |
Ge4+ + 4e− → Ge0 m/z = 18.2 g mol−1 | (8) |
Ge2+ + 2e− → Ge0 m/z = 36.3 g mol−1 | (9) |
The first reduction peak was assigned to the reduction of Ge(IV) to Ge(II). Thus, no mass increase was expected at this potential range. However a small mass increase was observed and the increase of mass stopped when reached a certain value. This is consistent with the observation of Endres and co-workers using a scanning tunneling microscope (STM).16 They found the growth of germanium islands at the beginning of the first reduction peak and the formation of a coherent, closed germanium layer when the potential was scanned to slightly more negative values than the first reduction peak. This layer hardly changed until the beginning of the second reduction peak.16 Xie et al. explained that two electrochemical reactions take place at the first reduction peak: the reduction of Ge(IV) to Ge(II) and the underpotential deposition (UPD) of germanium.36 At the second reduction wave, the potential is negative enough for reaction (9) to take place. In the beginning, the reduction rate of Ge(II) to Ge(0) was not fast enough to catch up with the rate of formation of Ge(II) so the m/z value increased from 0 to 65 g mol−1 as the potential scanned to more negative values. Based on eqn (8) and (9), the m/z value should not exceed 36.3 g mol−1. The morphology of the germanium film led to this abnormal increase in m/z value. Endres and co-workers found germanium nanoclusters forming during cathodic scan from ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate containing GeCl4.16 The roughness of the germanium surface leads to the increase in frequency change which can be explained by several possible mechanisms.37 This also can be reflected from the ratio between resonance frequency change (Δf) and resistance change (ΔR) of the crystal:38
![]() | (10) |
On the cathodic back scan, a mass decrease was observed from −1.6 V on, due to the chemical dissolution of germanium deposit via the comproportionation reaction:
Ge4+ + Ge0 ⇌ 2Ge2+. | (11) |
The rotating-ring disk electrode experiments provide clear evidence of the formation of Ge(II) at the first reduction peak. A cyclic voltammogram was performed on the disk and a constant potential of +1.3 V was applied on the ring (Fig. 9). At the first reduction plateau r′1, Ge(IV) was reduced to Ge(II) and then the Ge(II) convected to the ring and this Ge(II) was oxidized back to Ge(IV) on the ring. Thus, a corresponding current a′1 was observed on the ring. At the second reduction wave r′2, Ge(II) was reduced to Ge(0), and no oxidation current is expected on the ring. However, an anodic current a′2 was observed. This is because chloride ions are liberated from the germanium complex when Ge(II) is reduced to Ge(0). The chloride ions were convected to the ring and were oxidized to chlorine gas. The formation of germanium on the disk led to the passivation of the electrode, and as a result, the disk current decreased. At the third reduction plateau r′3, Ge(IV) was reduced to Ge(II) which is the same reaction on r′1, but the current is much lower. In order to prevent the oxidation of chloride ions on the ring, the ring potential was changed to +0.65 V where Ge(II) can be oxidized to Ge(IV) but not positive enough for oxidizing chloride ions. The result is shown in Fig. 10. At the first reduction peak, a ring current was observed. The ring current was lower than the limiting current due to the applied potential was not positive enough. At the second reduction peak, the ring current dropped to zero.
Germanium films were electrodeposited from [BMP][Tf2N] solutions at elevated temperatures in order to investigate their morphologies. Fig. 11a shows the SEM pictures of the germanium film electrodeposited at 150 °C. The film was electrodeposited at −1.2 V with an average current density of −0.35 A dm−2, and the theoretical thickness calculated from the charge was 4.8 μm. The germanium film had a very flat and uniform morphology, but there were a few cracks on the macroscale (see ESI†). In the EDX spectrum, a very small oxygen peak was observed which was due to the oxidation of germanium in the air. A chlorine peak was also found in the EDX. Endres and co-workers attributed the presence of chlorine to GeCl3 termination of the deposit-electrolyte interface.18Fig. 11c shows SEM picture of the germanium film electrodeposited at −0.9 V at 180 °C. The EDX spectrum for this film shows a very small oxygen peak and barely a chlorine peak. The film deposited at 180 °C had a grey but shiny metallic appearance, and no cracks were found in the film (see ESI†). The average current density was −0.46 A dm−2 and the theoretical thickness was 5.8 μm. Increasing the deposition temperature, not only increased the deposition rate, but also prevented the formation of cracks in the dense films. Dissolution of the p-type germanium anode was observed during electrodeposition. The surface of the germanium wafer became rough. The color of the solution did not change after electrodeposition.
The electrodeposited germanium film was removed from the substrate using resin and analyzed by XRD. No diffraction peaks were observed for the germanium film which indicates that the electrodeposited germanium on platinum was amorphous. Germanium was also electrodeposited on a copper substrate, however, XRD diffraction peaks for Cu3Ge alloy were observed. This suggests that electrodeposited germanium formed an alloy with the copper substrate (Fig. 12).
Maldonado and co-workers were the first to report the epitaxial electrodeposition of germanium nanowires from an aqueous solution, and their work required the formation of gallium nanodroplets.40 In principle, at elevated temperature, due to the increase of the adatom mobility epitaxial growth of germanium on germanium substrate can be achieved if the surface of the germanium substrate is free of contaminations like oxides, grease, etc. The n-type germanium(100) substrates were rinsed with deionized water before using to remove most of the native oxides on the surface. Also, thanks to the comproportionation reaction (11), germanium substrates should be “self-cleaned” in the [BMP][Tf2N] solution containing GeCl4. This was supposed to prevent the existence of a native oxide layer between the germanium wafer and the electrolyte. However, the transmission electron microscopy (TEM) picture of the cross-section of the germanium layer deposited on germanium substrate shows the interface was not clean (Fig. 13). The electron diffraction patterns indicates that the deposited germanium film was amorphous whereas the substrate was single crystalline. In order to eliminate oxygen from the germanium substrates, a positive potential of +1.0 V was applied for different times (3 s, 10 s, 15 s and 20 s) before deposition to dissolve top layer of germanium. The films were characterized by the electron backscatter diffraction (EBSD). Kikuchi pattern of germanium was always found on the substrates, but the electrodeposited films did not give rise to any Kikuchi diffraction patterns. Epitaxial growth of germanium was not successful even with the pre-dissolution of germanium wafer before deposition.
Fig. 14 shows the SEM image of the cross-section of a thick germanium film (75 μm thick) electrodeposited on germanium. The film was very dense but partially delaminated from the substrate. The deposition rate reached about 6.0 μm h−1. The energy-dispersive X-ray spectroscopy (EDS) illustrates the presence of chlorine as well as oxygen and carbon impurities. The purity of the germanium film was further analyzed using Auger electron spectroscopy (AES) (Fig. 15). Without etching, carbon and oxygen were detected on the surface of the electrodeposited germanium and the germanium peaks were almost invisible which means the germanium surface was covered with a contamination layer. After the first etching cycle, the oxygen and carbon peaks reduced and germanium peaks can be clearly observed. However a small peak at about 184 eV appeared which is associated with chlorine. Carbon and oxygen peaks were vanished after four etching cycles, but the chlorine peak was still there. The concentration of chlorine in germanium is difficult to quantify due to the low signal intensity and thus a low signal-to-noise ratio, therefore no proper peak fitting could be obtained. The presence of those impurities in the film can be another reason for the absence of epitaxial growth.
![]() | ||
Fig. 15 Auger electron spectra of the germanium film deposited on an n-type germanium substrate from 0.5 M GeCl4 in [BMP][Tf2N] at 180 °C at −0.9 V vs. Pt. |
Footnote |
† Electronic supplementary information (ESI) available: SEM images of the germanium film electrodeposited from [BMP][DCA] and [BMP][Tf2N]; a photograph of a germanium film electrodeposited from [BMP][Tf2N]; linear scan voltammograms of 0.5 M GeCl4 in [BMP][Tf2N]; viscosity of [BMP][Tf2N] at different temperatures. See DOI: 10.1039/c4cp06076h |
This journal is © the Owner Societies 2015 |