George M. Whitesides*
Department of Chemistry and Chemical Biology, Harvard University, 12 Oxford Street, Cambridge, USA. E-mail: gwhitesides@gmwgroup.harvard.edu
First published on 21st August 2013
Although the challenges of inexpensive, self-contained medical diagnostics are often phrased in terms of medical needs encountered in, say, the rural villages and large urban slums of Africa, practical solutions to these challenges would also be widely useful in many other circumstances: examples of other types of applications that share at least some technical requirements include medical diagnosis in military field operations, detection of diseases of animals and plants, verification of food and water safety, environmental monitoring, analyses for homeland security, and chronic and point-of-care health monitoring. In each area, specific applications require some combination of simplicity, robustness, and low cost. New methods applicable to one have the potential to be applicable to others.
Making diagnostics reliable without the infrastructure usually available in a well-supported academic laboratory (where much of the LoC technology has originated) is more difficult than it seems. The characteristics that must be built into a successful system make a long list, and sometimes seem incompatible; for example: how can unskilled personnel accurately measure the intensity of color in a colorimetric assay? How can one use the reliable, workhorse reagents (e.g., common enzymes and antibodies) of bioanalysis if they are unstable in the environments in which they must be used? Because the list is so long, there will probably be no single, best solution, but rather ingenious solutions for each problem that will then be combined in packages tailored to specific applications.
Lutz et al.1 demonstrate that it is possible to achieve controllably variable timing in paper microfluidic systems by using solid sugars deposited in the channels to provide time delays; they further show that this type of system provides the basis for the timed addition of reagents and washes required in a protocol modeled on the familiar lateral flow immunoassay. A number of methods of controlling the valving of flows through channels have been demonstrated in the past. In particular, Paul Yager2 showed that sugars provided the basis for valving in paper microchannels, and Scott Phillips et al.3,4 offered an alternative method based on the use of wax to tailor the hydrophilic/hydrophobic balance of the channels, and thus the flow through them. The paper by Lutz1 carries this approach further, and places it on a more quantitative engineering footing, in two steps: (i) They analyze the characteristics of the flows through channels in which movement of a capillarity-driven liquid front was accompanied by solution of solid sugar deposited on the paper, and demonstrate that the success of the sugar-based “delay lines” depend primarily on the viscosity of the solution moving through them (highly concentrated, viscous solutions of sugars move more slowly; less concentrated, less viscous solutions move more rapidly). (ii) They design (using their understanding of these flow characteristics) an ingenious gold-amplified immunoassay, in which the timing of the addition of samples, washes, and reagents is controlled by the amount of sugar deposited on the paper in the channels. It is an elegant idea, and one that fits naturally into facts that suggest it has characteristics required of a technique that is to become a component of the technology of paper diagnostics: in particular, it is inexpensive and simple, and sugars are already commonly used as additives to stabilize proteins against degradation and loss of activity upon storage in the dry state.
This journal is © The Royal Society of Chemistry 2013 |