Detection of 2,4-Dichlorophenoxyacetic Acid Using a Fluorescence Immunoanalyzer

(Note: The full text of this document is currently only available in the PDF Version )

Kim R. Rogers, Steven D. Kohl, Lee A. Riddick, Kim R. Rogers and Thomas Glass


Abstract

A flow immunoassay method for the measurement of 2,4-dichlorophenoxyacetic acid (2,4-D) was developed. The competitive fluorescence immunoassay relies on the use of antibody- or antigen-coated poly(methyl methacrylate) particles (98 µm diameter) as a renewable solid phase. The assay exhibits a dynamic range of 0.1–100 µg l1 using a monoclonal antibody or alternatively 10 µg l1 to 10 mg l1 using commercially available antiserum. The assay is demonstrated in buffered saline solution as well as in aquatic environmental media. The relative errors for the environmental matrices were similar to those for the buffer control. The precision of concentration values calculated at 1 mg l1 (for the assay using antiserum) were ±0.28, ±0.27 and ±0.43 mg l1 for the buffer, well water and river water matrices, respectively. The method shows cross-reactivity with compounds of closely related structure but little cross-reactivity with compounds dissimilar in structure to 2,4-D. The proposed automated competitive immunoassay method is rapid (between 7 and 15 min per assay), simple and potentially portable.


References

  1. E. P. Meulenberg, W. H. Mulder and P. G. Stoks, Environ. Sci. Technol., 1995, 29, 553 CAS.
  2. J. C. Hall, R. J. A. Deschamps and K. K. Krieg, J. Agric. Food Chem., 1989, 37, 981 CrossRef CAS.
  3. A. Dzgoev, M. Mecklenburg, P.-O. Larson and B. Danielsson, Anal. Chem., 1996, 68, 3364 CrossRef CAS.
  4. C. G. Bauer, A. V. Eremenko, E. Ehrentreich-Forster, F. F. Bier, A. Makowwer, H. B. Halsall, W. R. Heineman and F. W. Scheller, Anal. Chem., 1996, 68, 24S3 CrossRef CAS.
  5. C. Dohrman, Anal. Environ. Lab., 1991, October, 31 Search PubMed.
  6. J. Fleeker, J. Assoc. Off. Anal. Chem., 1994, 70, 874 Search PubMed.
  7. R. A. Ogert, A. W. Kusterbeck, G. A. Wemhoff, R. Burke and F. S. Ligler, Anal. Lett., 1992, 25, 1999 CAS.
  8. J. P. Alarie, J. R. Bowyer, M. J. Sepaniac, A. M. Hoyt and T. Vo-Dinh, Anal. Chim. Acta, 1990, 236, 237 CrossRef CAS.
  9. C. H. Pollema and J. Ruzicka, Anal. Chem., 1994, 66, 1825 CrossRef CAS.
  10. M. Mayer and J. Ruzicka, Anal. Chem., 1996, 68, 3808 CrossRef CAS.
  11. T. S. Lawruk, C. S. Hottenstein, J. R. Fleeker, J. C. Hall, D. Herzog and F. M. Rubio, Bull. Environ. Contam. Toxicol., 1994, 52, 538 CrossRef CAS.
  12. Y. V. Lukin, I. M. Dokuchaer, I. M. Polyak and S. A. Eremin., Anal. Lett., 1994, 27, 2973 CAS.
  13. S. A. Eremin, J. Landon, D. S. Smith and R. Jackman, in Food Safety and Quality Assurance: Applications of Immunoassay Systems, ed. Morgan, M. R. A., Smith, C. J., and Williams, P. A., Elsevier Applied Science, New York, 1992 Search PubMed.
  14. Y. Gu, D. B. Knaebel, R. A. Korus and R. L. Crawford, Environ. Sci. Technol., 1995, 29, 1622 CAS.
  15. A. A. Suleiman and G. G. Guilbault, Analyst, l994, 119, 2279 Search PubMed.
  16. M. Minunni, P. Skladal and M. Mascini, Anal. Lett., 1994, 27, 1475 CAS.
  17. P. Skladal and T. Kalab, Anal. Chim. Acta, 1995, 316, 73 CrossRef CAS.
  18. M. Pourfarzaneh, G. W. White, J. Landon and D. S. Smith, Clin. Chem., 1980, 26, 730 CAS.
  19. S. A. Eremin, in Immunoanalysis of Agrochemicals, Emerging Technologies, ACS Symposium Series 586, ed. Nelson, J. O., Karu, A. E., and Wong, R. B., American Chemical Society, Washington, DC, 1995 Search PubMed.
  20. I. Howes, in Immunoassays Essential Data, ed. Edwards, R., Wiley, New York, 1996 Search PubMed.