Optimisation of dynamic reaction cell (DRC)-ICP-MS for the determination of 42Ca/43Ca and 44Ca/43Ca isotope ratios in human urine

Abstract

A new method for the measurement of calcium isotope ratios (42Ca/43Ca and 44Ca/43Ca) in urine using DRC-ICP-MS after oxalate precipitation is presented. The isotope ratios were measured with a precision of approximately 0.15% RSD, limited only by counting statistics in samples diluted to a total calcium concentration of 3–4 mg L−1. The observed mass bias was substantial, approximately 5–10% per u. Careful mass bias correction using matrix and concentration matched solutions was essential and necessary in order to obtain accurate results. A methane gas flow of 0.6 ml min−1 was used as a reaction gas in the dynamic reaction cell to remove polyatomic interferences (e.g., 40Ar+ and 40ArH2+). Unfortunately, other interferences are formed in the dynamic reaction cell from secondary reactions with methane adducts. An interfering ion observed at m/z = 43 with a precursor ion of m/z = 17 was removed by applying an Rpq setting of 0.4, while an interfering ion on m/z = 48 with a precursor ion of m/z = 37 could not be removed. Despite the fact that the 40Ar interference was successfully removed by the methane reaction gas, it was not possible to measure the 44Ca/40Ca and 42Ca/40Ca ratios with a precision only limited by counting statistics, most likely due to uncertainties from the detection system when measuring high count rates. The developed method was successfully applied for the calcium isotope ratio analysis of human urine samples enriched in 42Ca and 44Ca. It was found that an atom enrichment of 1.3% was needed in the urine samples in order to obtain reliable results.

Graphical abstract: Optimisation of dynamic reaction cell (DRC)-ICP-MS for the determination of 42Ca/43Ca and 44Ca/43Ca isotope ratios in human urine

Article information

Article type
Paper
Submitted
18 Aug 2005
Accepted
03 Jan 2006
First published
30 Jan 2006

J. Anal. At. Spectrom., 2006,21, 297-304

Optimisation of dynamic reaction cell (DRC)-ICP-MS for the determination of 42Ca/43Ca and 44Ca/43Ca isotope ratios in human urine

S. Stürup, L. Bendahl and B. Gammelgaard, J. Anal. At. Spectrom., 2006, 21, 297 DOI: 10.1039/B511741K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements