Issue 9, 2008

The equivalence of diffusive samplers to reference methods for monitoring O3, benzene and NO2 in ambient air

Abstract

A study of the equivalence to the reference methods of the Radiello samplers for ozone (O3) and benzene as well as the membrane-closed Palmes tube (MCPT) for nitrogen dioxide (NO2) is presented. These samplers benefit from new model equations capable of estimating their uptake rate. For O3, the aim here was to demonstrate the equivalence for the reference period of 8 h and 120 µg m−3, the target value of the 3rd European Daughter Directive. For benzene, the demonstration of equivalence to the annual limit value of 5 µg m−3 of the 2nd European Daughter Directive was examined. In the case of NO2, the equivalence to the annual limit value of the 1st European Daughter Directive (40 µg m−3) was considered. Results show that the radial sampler for O3 fails to meet the Data Quality Objective (DQO) for continuous monitoring. However, with an expanded uncertainty of less than 30%, the O3 diffusive sampler fulfils the DQO for indicative measurements. For benzene, the Radiello sampler exposed for 7 days gave satisfying results showing the ability of the sampler to meet the DQO of the reference method. Nevertheless, the field tests should be complemented by measurements for a wider range of benzene concentrations. In the case of NO2, all the results of the laboratory and field experiments respected the requirements necessary for the demonstration of equivalence. Overall, these findings thus show that the Radiello sampler and the MCPT are equivalent to the reference methods only for assessment of benzene and NO2, respectively.

Graphical abstract: The equivalence of diffusive samplers to reference methods for monitoring O3, benzene and NO2 in ambient air

Article information

Article type
Paper
Submitted
11 Feb 2008
Accepted
25 Jul 2008
First published
07 Aug 2008

J. Environ. Monit., 2008,10, 1052-1059

The equivalence of diffusive samplers to reference methods for monitoring O3, benzene and NO2 in ambient air

D. Buzica, M. Gerboles and H. Plaisance, J. Environ. Monit., 2008, 10, 1052 DOI: 10.1039/B802260G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.