Investigation of arsenic speciation on drinking water treatment media utilizing automated sequential continuous flow extraction with IC-ICP-MS detection

Abstract

Three treatment media, used for the removal of arsenic from drinking water, were sequentially extracted using 10 mM MgCl2 (pH 8), 10 mM NaH2PO4 (pH 7) followed by 10 mM (NH4)2C2O4 (pH 3). The media were extracted using an on-line automated continuous extraction system which allowed the arsenic in each of the extraction fluids to be speciated on-line using IC-ICP-MS. The 10 mM MgCl2 preferentially extracted As(III) from each of the media. The percentage of the arsenic extracted by the MgCl2, relative to a HNO3/H2O2 digestion of the media, ranged from 0.1–2.3% for the three solids. The next sequential extraction fluid, 10 mM NaH2PO4, extracted some of the residual As(III) remaining on each of the media but the predominant species extracted was As(V). The 10 mM NaH2PO4 extracted 15.3 to 42.8% of the total arsenic relative to a total digested concentration for each of the media. The As(III) and As(V) stability studies conducted in these two extraction fluids indicated that conversion between As(III) and As(V) was not significant for the short extraction fluid sample contact time associated with the on-line continuous flow extraction cell. Finally, the 10 mM (NH4)2C2O4 extraction fluid was utilized in an off-line analysis mode because the Fe and As concentrations extracted from the media were not compatible with direct ICP-MS detection. The (NH4)2C2O4 extracted 2.9–29% As(III) for all three media and caused an oxidation of As(III) to As(V) during the extraction period for one of the three media. The sum of the arsenic from each of the three extraction fluids represented 92%, 44% and 53% of the available total arsenic for the three media, respectively. The speciation results for each media were obtained by adding all the speciation results from all three extraction fluids together and the resulting distribution of As(III)/As(V) compared well with the speciation results obtained via XANES.

Graphical abstract: Investigation of arsenic speciation on drinking water treatment media utilizing automated sequential continuous flow extraction with IC-ICP-MS detection

Supplementary files

Article information

Article type
Paper
Submitted
27 May 2005
Accepted
25 Aug 2005
First published
15 Sep 2005

J. Environ. Monit., 2005,7, 1079-1084

Investigation of arsenic speciation on drinking water treatment media utilizing automated sequential continuous flow extraction with IC-ICP-MS detection

P. A. Creed, C. A. Schwegel and J. T. Creed, J. Environ. Monit., 2005, 7, 1079 DOI: 10.1039/B507568H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements