Issue 48, 2017

Characterizing protein–protein-interaction in high-concentration monoclonal antibody systems with the quartz crystal microbalance

Abstract

Making use of a quartz crystal microbalance (QCM), concentrated solutions of therapeutic antibodies were studied with respect to their behavior under shear excitation with frequencies in the MHz range. At high protein concentration and neutral pH, viscoelastic behavior was found in the sense that the storage modulus, G′, was nonzero. Fits of the frequency dependence of G′(ω) and G′′(ω) (G′′ being the loss modulus) using the Maxwell-model produced good agreement with the experimental data. The fit parameters were the relaxation time, τ, and the shear modulus at the inverse relaxation time, G* (at the “cross-over frequency” ωC = 1/τ). The influence of two different pharmaceutical excipients (histidine and citrate) was studied at variable concentrations of the antibody and variable pH. In cases, where viscoelasticity was observed, G* was in the range of a few kPa, consistent with entropy-driven interactions. τ was small at low pH, where the antibody carries a positive charge. τ increased with increasing pH. The relaxation time τ was found to be correlated with other parameters quantifying protein–protein interactions, namely the steady shear viscosity (η), the second osmotic virial coefficient as determined with both self-interaction chromatography (B22,SIC) and static light scattering (B22,SLS), and the diffusion interaction parameter as determined with dynamic light scattering (kD). While B22 and kD describe protein–protein interactions in diluted samples, the QCM can be applied to concentrated solutions, thereby being sensitive to higher-order protein–protein interactions.

Graphical abstract: Characterizing protein–protein-interaction in high-concentration monoclonal antibody systems with the quartz crystal microbalance

Supplementary files

Article information

Article type
Paper
Submitted
21 Aug 2017
Accepted
13 Nov 2017
First published
13 Nov 2017

Phys. Chem. Chem. Phys., 2017,19, 32698-32707

Characterizing protein–protein-interaction in high-concentration monoclonal antibody systems with the quartz crystal microbalance

J. Hartl, A. Peschel, D. Johannsmann and P. Garidel, Phys. Chem. Chem. Phys., 2017, 19, 32698 DOI: 10.1039/C7CP05711C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements