Issue 17, 2011

Varying nanoparticle pseudostationary phase plug length during capillary electrophoresis

Abstract

Capillary electrophoresis based separations of the hypothesized Parkinson's disease biomarkers dopamine, epinephrine, pyrocatechol, L-3,4-dihydroxyphenylalanine (L-DOPA), glutathione, and uric acid are performed in the presence of a 1 nM 11-mercaptoundecanoic acid functionalized gold (Au@MUA) nanoparticle pseudostationary phase plug. Au@MUA nanoparticles are monitored in the capillary and remain stable in the presence of electrically-driven flow. Migration times, peak areas, and relative velocity changes (vs. no pseudostationary) are monitored upon varying (1) the Au@MUA nanoparticle pseudostationary phase plug length at a fixed separation voltage and (2) the separation voltage for a fixed Au@MUA nanoparticle pseudostationary phase plug length. For instance, the migration times of positively charged dopamine and epinephrine increase slightly as the nanoparticle pseudostationary phase plug length increases with concomitant decreases in peak areas and relative velocities as a result of attractive forces between the positively charged analytes and the negatively charged nanoparticles. Migration times for neutral pyrocatechol and slightly negative L-DOPA did not exhibit significant changes with increasing nanoparticle pseudostationary plug length; however, reduction in peak areas for these two molecules were evident and attributed to non-specific interactions (i.e.hydrogen bonding and van der Waals interactions) between the biomarkers and nanoparticles. Moreover, negatively charged uric acid and glutathione displayed progressively decreasing migration times and peak areas and as a result, increased relative velocities with increasing nanoparticle pseudostationary phase plug length. These trends are attributed to partitioning and exchanging with 11-mercaptoundecanoic acid on nanoparticle surfaces for uric acid and glutathione, respectively. Similar trends are observed when the separation voltage decreased thereby suggesting that nanoparticle-biomarker interaction time dictates these trends. Understanding these analyte migration time, peak area, and velocity trends will expand our insight for incorporating nanoparticles in separations.

Graphical abstract: Varying nanoparticle pseudostationary phase plug length during capillary electrophoresis

Article information

Article type
Paper
Submitted
06 Mar 2011
Accepted
14 Mar 2011
First published
05 Apr 2011

Analyst, 2011,136, 3469-3477

Varying nanoparticle pseudostationary phase plug length during capillary electrophoresis

V. Subramaniam, L. Griffith and A. J. Haes, Analyst, 2011, 136, 3469 DOI: 10.1039/C1AN15185A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.