The effect and potential of using a temperature controlled separation column with ultra-high pressure microcapillary liquid chromatography/tandem mass spectrometry on proteomic analysis

Abstract

The microcapillary liquid chromatography (µLC)/tandem mass spectrometry (MS/MS) system has become a prevailing analytical platform in proteomics. Typical proteomic studies aimed at proteome-wide identification of peptides and proteins rely heavily on producing an accurate and reproducible solvent-composition gradient throughout microcapillary separation columns to improve LC separation. With the recent advent of targeted proteomic approaches utilizing the LC retention time as a physicochemical parameter for peptides, high reproducibility of LC separation additionally becomes an important factor. In this study, column temperature elevation is utilized to improve reproducibility and separation efficiency of the µLC-MS/MS system. The simple incorporation of a semi-rigid gas line heater allowed precise control of the temperature of microcapillary columns longer than 70 cm, up to 60 °C. Tryptic enolase peptides were used as a standard sample to evaluate the effect of the controlled temperature elevation on the peptide separation efficiency and reproducibility. In addition to the increased reproducibility in peptide elution time due to the controlled column temperature, the temperature elevation resulted in a decrease in the column operation pressure, which, in turn, allowed a higher solvent flow-rate to be employed using the same LC pumps, leading to further improvements in the performance of µLC systems.

Graphical abstract: The effect and potential of using a temperature controlled separation column with ultra-high pressure microcapillary liquid chromatography/tandem mass spectrometry on proteomic analysis

Supplementary files

Article information

Article type
Paper
Submitted
15 Sep 2010
Accepted
01 Mar 2011
First published
24 Mar 2011

Analyst, 2011,136, 2100-2105

The effect and potential of using a temperature controlled separation column with ultra-high pressure microcapillary liquid chromatography/tandem mass spectrometry on proteomic analysis

S. Hyung, M. Kim, D. Mun, H. Lee and S. Lee, Analyst, 2011, 136, 2100 DOI: 10.1039/C0AN00724B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements