Issue 5, 2001

Application of central composite designs for optimisation of the chromatographic separation of monomethylarsonate and dimethylarsinate and of selenomethionine and selenite by ion-pair chromatography coupled with plasma mass spectrometric detection

Abstract

Central composite designs (CCDs) were used in the study of the ion-pair chromatographic separation of arsenic and selenium species in tap water: monomethylarsonate, dimethylarsinate, selenomethionine and selenite. The ternary eluent consisted of tetrabutylammonium phosphate (TBA), sodium hydrogenphosphate (Na2HPO4) and 1% acetonitrile. CCD allowed the investigation of the influence of the eluent parameters, which varied from 0.5 to 4.2 mmol l−1 Na2HPO4, 0.5 to 4.2 mmol l−1 TBA and pH 4.9 to 8.2, on the capacity factors (k′) of arsenic and selenium compounds. Furthermore, another mathematical model that permitted the variation of the chromatographic selectivity of species, computed from their retention data to be followed, was investigated. This showed the ability to locate the optimum conditions within the experimental design, so that arsenic and selenium species could be simultaneously quantified with good efficiency and resolution. A comparison between the predicted and the experimental response values was made in order to assess the prediction quality of the model. Response surfaces and isoresponse curves obtained from the mathematical models allowed the determination of the optimum chromatographic conditions and the robustness of the method. The predicted optimum zone allowing satisfactory determination of both arsenic and selenium compounds was pH 5.5–6.5, 2.5 mmol l−1 Na2HPO4 and 3.0–4.0 mmol l−1 TBA.

Article information

Article type
Paper
Submitted
10 Oct 2000
Accepted
22 Feb 2001
First published
30 Mar 2001

Analyst, 2001,126, 594-601

Application of central composite designs for optimisation of the chromatographic separation of monomethylarsonate and dimethylarsinate and of selenomethionine and selenite by ion-pair chromatography coupled with plasma mass spectrometric detection

B. Do, S. Robinet, D. Pradeau and F. Guyon, Analyst, 2001, 126, 594 DOI: 10.1039/B008169H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements