Issue 7, 2024

The development and validation of a liquid chromatography tandem mass spectrometry method for the quantification of selinexor and its application in Chinese multiple myeloma patients

Abstract

Selinexor is a nuclear exportin-1 (XPO1) inhibitor that has been approved for the treatment of multiple myeloma patients. However, sustained use of selinexor may result in some undesirable consequences. Furthermore, selinexor has moderate inter-patient variability. Herein, we developed an ultrahigh-performance liquid chromatography tandem mass spectrometry method for measuring selinexor levels in human plasma ranging from 1 to 1000 ng mL−1. Furthermore, the developed approach was validated in accordance with FDA criteria. The established approach demonstrated inter-day and intra-day precision, expressed as the relative standard deviation, of less than 8%, with accuracies of less than 6%, expressed as relative error. The results showed that the protein depletion was quite complete for selinexor extraction, with recoveries ranging from 85.89 to 108.38%. The validated method facilitates the quantitation of selinexor in multiple myeloma patients. The selinexor plasma concentration exhibits obvious inter-patient' variability after administration. Thus, it is necessary to make a personalized prescription through therapeutic drug monitoring. Furthermore, the change in platelet counts before and after selinexor treatment was shown to be related to the plasma concentration at 3 h after administration, which provides the basis for therapeutic drug monitoring sampling time points and a method for predicting the occurrence of thrombocytopenia. In conclusion, the developed method can be used for the quantification of the plasma concentration of selinexor, and it is of great significance to conduct therapeutic drug monitoring for patients taking selinexor in order to enhance therapeutic effects and prevent the occurrence of adverse reactions.

Graphical abstract: The development and validation of a liquid chromatography tandem mass spectrometry method for the quantification of selinexor and its application in Chinese multiple myeloma patients

Article information

Article type
Paper
Submitted
05 Dec 2023
Accepted
09 Jan 2024
First published
10 Jan 2024

Anal. Methods, 2024,16, 1050-1057

The development and validation of a liquid chromatography tandem mass spectrometry method for the quantification of selinexor and its application in Chinese multiple myeloma patients

X. Yan, X. He, X. Yang, Q. Zhao and Y. Lou, Anal. Methods, 2024, 16, 1050 DOI: 10.1039/D3AY02166A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements