Issue 1, 2022

Tandem-column extraction chromatography for Nd separation: minimizing mass-independent isotope fractionation for ultrahigh-precision Nd isotope-ratio analysis

Abstract

The short-lived 146Sm–142Nd isotope system traces key early planetary differentiation processes that occurred during the first 500 million-years of the solar system history. The variations of 142Nd/144Nd in terrestrial samples, typically within a range of ±20 ppm, are determined using high-precision mass spectrometry that requires quantitative separation of Nd from all other elements in the sample, including the neighboring lanthanides. Recent improvements in mass spectrometry have pushed the analytical precision of 142Nd/144Nd measurements down to ∼2 ppm. Non-mass-dependent isotope fractionation produced during Nd separation, however, is a major factor limiting the quality of the 142Nd data. Popular chemical separation methods using Ln resins have unpredictable nuclear field shift effects that generate anomalous Nd isotope ratios. In order to solve this problem and potentially resolve small 142Nd/144Nd variations within ±5 ppm, in this study, we present a new two-step column separation method that effectively removes the isobaric interferents of Ce, Pr and Sm, with a recovery rate of Nd greater than 98%. JNdi-1 standard solutions doped with these interfering elements and geological reference materials are tested to document the performance of this method. A set of titanite samples from the Pilbara Craton in western Australia were also investigated to test the potential isotope fractionation effects. The same samples were processed using our method and the widely used Ln method. In contrast to the nuclear field shift effects observed from the samples using the Ln method, the results based on our new method show no detectable isotope fractionation, which further confirms the reliability of this new column chemistry scheme that is optimized for ppm-level precision Nd isotope ratio measurement, especially for resolving small variations in 142Nd/144Nd caused by the decay of 146Sm.

Graphical abstract: Tandem-column extraction chromatography for Nd separation: minimizing mass-independent isotope fractionation for ultrahigh-precision Nd isotope-ratio analysis

Supplementary files

Article information

Article type
Paper
Submitted
22 Oct 2021
Accepted
02 Dec 2021
First published
02 Dec 2021

J. Anal. At. Spectrom., 2022,37, 185-193

Tandem-column extraction chromatography for Nd separation: minimizing mass-independent isotope fractionation for ultrahigh-precision Nd isotope-ratio analysis

D. Wang and R. W. Carlson, J. Anal. At. Spectrom., 2022, 37, 185 DOI: 10.1039/D1JA00365H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements