Scattering and absorption differ drastically in their inner filter effects on fluorescence, resonance synchronous, and polarized resonance synchronous spectroscopic measurements

Author affiliations

Abstract

The sample inner filter effect (IFE) induces spectral distortion and affects the linearity between intensity and analyte concentration in fluorescence, Raman, surface enhanced Raman, and Rayleigh light scattering measurements. Existing spectrofluorometric-based measurements treat light scattering and absorption identically in their sample IFEs. Reported herein is the finding that photon scattering and absorption differ drastically in inducing the sample IFE in Stokes-shifted fluorescence (SSF) spectrum, resonance synchronous spectrum (RS2), and the polarized resonance synchronous spectrum (PRS2) measurements. Absorption with an absorption extinction as small as 0.05 imposes significant IFE on SSF, RS2, and PRS2 measurements. However, no significant IFE occurs even when the scattering extinction is as high as 0.9. For samples that both absorb and scatter light, one should decompose their UV-vis extinction spectra into absorption and scattering extinction component spectra before correcting the sample IFE. An iteration PRS2 method was introduced for the experimental decoupling of the photon absorption and scattering contribution. The methodology presented in this work can be easily implemented by researchers with access to one conventional UV-vis spectrophotometer and one spectrofluorometer equipped with a pair of excitation and detection polarizers. This work should be of broad significance in chemical research given the popularity of fluorescence spectroscopy in material characterization applications.

Graphical abstract: Scattering and absorption differ drastically in their inner filter effects on fluorescence, resonance synchronous, and polarized resonance synchronous spectroscopic measurements

Back to tab navigation

Supplementary files

Publication details

The article was received on 27 Apr 2018, accepted on 30 May 2018 and first published on 31 May 2018


Article type: Paper
DOI: 10.1039/C8AN00790J
Citation: Analyst, 2018, Advance Article
  •   Request permissions

    Scattering and absorption differ drastically in their inner filter effects on fluorescence, resonance synchronous, and polarized resonance synchronous spectroscopic measurements

    J. X. Xu, B. C. N. Vithanage, S. A. Athukorale and D. Zhang, Analyst, 2018, Advance Article , DOI: 10.1039/C8AN00790J