Jump to main content
Jump to site search

Volume 187, 2016
Previous Article Next Article

Multi-centre Raman spectral mapping of oesophageal cancer tissues: a study to assess system transferability

Author affiliations

Abstract

The potential for Raman spectroscopy to provide early and improved diagnosis on a wide range of tissue and biopsy samples in situ is well documented. The standard histopathology diagnostic methods of reviewing H&E and/or immunohistochemical (IHC) stained tissue sections provides valuable clinical information, but requires both logistics (review, analysis and interpretation by an expert) and costly processing and reagents. Vibrational spectroscopy offers a complimentary diagnostic tool providing specific and multiplexed information relating to molecular structure and composition, but is not yet used to a significant extent in a clinical setting. One of the challenges for clinical implementation is that each Raman spectrometer system will have different characteristics and therefore spectra are not readily compatible between systems. This is essential for clinical implementation where classification models are used to compare measured biochemical or tissue spectra against a library training dataset. In this study, we demonstrate the development and validation of a classification model to discriminate between adenocarcinoma (AC) and non-cancerous intraepithelial metaplasia (IM) oesophageal tissue samples, measured on three different Raman instruments across three different locations. Spectra were corrected using system transfer spectral correction algorithms including wavenumber shift (offset) correction, instrument response correction and baseline removal. The results from this study indicate that the combined correction methods do minimize the instrument and sample quality variations within and between the instrument sites. However, more tissue samples of varying pathology states and greater tissue area coverage (per sample) are needed to properly assess the ability of Raman spectroscopy and system transferability algorithms over multiple instrument sites.

Back to tab navigation

Publication details

The article was received on 18 Nov 2015, accepted on 17 Dec 2015 and first published on 17 Dec 2015


Article type: Paper
DOI: 10.1039/C5FD00183H
Author version available: Download Author version (PDF)
Citation: Faraday Discuss., 2016,187, 87-103
  •   Request permissions

    Multi-centre Raman spectral mapping of oesophageal cancer tissues: a study to assess system transferability

    M. Isabelle, J. Dorney, A. Lewis, G. R. Lloyd, O. Old, N. Shepherd, M. Rodriguez-Justo, H. Barr, K. Lau, I. Bell, S. Ohrel, G. Thomas, N. Stone and C. Kendall, Faraday Discuss., 2016, 187, 87
    DOI: 10.1039/C5FD00183H

Search articles by author

Spotlight

Advertisements