Platinum stable isotope ratio measurements by double-spike multiple collector ICPMS

Author affiliations

Abstract

We present a new technique for the precise determination of platinum (Pt) stable isotope ratios by multiple-collector inductively coupled plasma mass spectrometry (MC-ICPMS) using two different Pt double-spikes (192Pt–198Pt and 196Pt–198Pt). Results are expressed relative to the IRMM-010 Pt isotope standard as the parts per million difference in 198Pt/194PtPt ratios (μ198Pt). Repeated measurements of the IRMM-010 Pt standard in two different laboratories, consuming ca. 40–85 ng of Pt, show that a long-term external reproducibility for μ192Pt of ≤40 ppm (2 sd; equivalent to ≤10 ppm u−1, where u is the unified atomic mass unit) can be obtained on Pt stable isotope ratios with either double-spike. Elemental doping tests reveal that double-spike corrected Pt stable isotope ratios are insensitive to the presence of relatively high (up to 10%) levels of matrix elements, although the 192Pt–198Pt double-spike is affected by an isobaric interference on 192Pt from 192Os. The 196Pt–198Pt double-spike does not use 192Pt in the double-spike inversion and is unaffected by Os contamination, and is our recommended double-spike for use with natural samples. As part of this study, we re-determined the natural Pt isotopic composition of IRMM-010 by MC-ICPMS using external element (Pb) doping to correct for instrumental mass bias and have identified relative Pt isotope differences of up to 10% from the reference values for this standard. The new isotopic composition of the IRMM-010 standard (190Pt = 0.01289%, 192Pt = 0.7938%, 194Pt = 32.81%, 195Pt = 33.79%, 196Pt = 25.29% and 198Pt = 7.308%) results in a redefined Pt atomic weight of 195.08395 ± 0.00068. Using our technique we have measured small, reproducible and statistically significant offsets in Pt stable isotope ratios between different Pt element standards and the IRMM-010 standard, which potentially indicates that natural Pt stable isotope fractionations exist that are larger than the reproducibility of our technique.

Graphical abstract: Platinum stable isotope ratio measurements by double-spike multiple collector ICPMS

Back to tab navigation

Supplementary files

Publication details

The article was received on 23 Jan 2013, accepted on 04 Mar 2013 and first published on 04 Mar 2013


Article type: Paper
DOI: 10.1039/C3JA50022E
Citation: J. Anal. At. Spectrom., 2013,28, 853-865
  •   Request permissions

    Platinum stable isotope ratio measurements by double-spike multiple collector ICPMS

    J. Creech, J. Baker, M. Handler, M. Schiller and M. Bizzarro, J. Anal. At. Spectrom., 2013, 28, 853
    DOI: 10.1039/C3JA50022E