Issue 16, 2012

Conformational relaxation dynamics of a poly(N-isopropylacrylamide) aqueous solution measured using the laser temperature jump transient grating method

Abstract

We observed phase transition and phase relaxation processes of a poly(N-isopropylacrylamide) (PNIPAM) aqueous solution using the heterodyne transient grating (HD-TG) method combined with the laser temperature jump technique. The sample temperature was instantaneously raised by about 1.0 K after irradiation of a pump pulse to crystal violet (CV) molecules for heating, and the phase transition was induced for the sample with an initial temperature just below the lower critical solution temperature (LCST); the following phase relaxation dynamics was observed. Turbidity relaxation was observed in both the turbidity and HD-TG responses, while another relaxation process was observed only in the HD-TG response, namely via the refractive index change. It is suggested that this response is due to formation of globule molecules or their assemblies since they would have nothing to do with turbidity change but would affect the refractive index, which is dependent on the molar volume of a chemical species. Furthermore, the grating spacing dependence of the HD-TG responses suggests that the response was caused by the counter propagating diffusion of the coil molecules as a reactant species and the globule molecules as a product species and the lifetime of the globule molecules ranged from 1.5 to 5 seconds. Thus, we conclude that the turbidity reflects the dynamics of aggregate conditions, not molecular conditions. The coil and globule sizes were estimated from the obtained diffusion coefficient. The sizes of the coil molecules did not change at the initial temperatures below the LCST but increased sharply as it approaches LCST. We propose that the coil-state molecules associate due to hydrophobic interaction when the initial temperature was higher than LCST minus 0.5 K and that the globule-state molecules generated from the coil-state molecules showed a similar trend in temperature. The phase transition was also induced by heating under a microscope, and the relaxation process was followed using the fluorescence peak shift of a fluorescent molecule-labeled PNIPAM. The result also supports the existence of a globule molecule or its assembly remains for several seconds in the phase relaxation.

Graphical abstract: Conformational relaxation dynamics of a poly(N-isopropylacrylamide) aqueous solution measured using the laser temperature jump transient grating method

Article information

Article type
Paper
Submitted
24 Jan 2012
Accepted
24 Feb 2012
First published
28 Feb 2012

Phys. Chem. Chem. Phys., 2012,14, 5620-5627

Conformational relaxation dynamics of a poly(N-isopropylacrylamide) aqueous solution measured using the laser temperature jump transient grating method

H. Inoue, K. Katayama, K. Iwai, A. Miura and H. Masuhara, Phys. Chem. Chem. Phys., 2012, 14, 5620 DOI: 10.1039/C2CP40243B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements