Analysis of immunoarrays using a gold grating-based dual mode surface plasmon-coupled emission (SPCE) sensor chip

Author affiliations

Abstract

We have developed a novel dual mode immunoassay platform that combines the advantages of real-time, label free measurement of surface plasmon resonance (SPR) and the highly directional surface plasmon-coupled emission (SPCE) using a gold grating-based sensor chip. Since only fluorophore-labeled analyte molecules that are close to the metal surface of the sensor chip will couple to the surface plasmon, SPCE detection is highly surface-specific leading to background suppression and increased sensitivity. Theoretical calculations were done to find SPR and SPCE angles for a sensor chip optimized for Alexa Fluor 647. We have confirmed the SPR and SPCE responses on the dual mode sensor chip using Alexa Fluor 647 labeled anti-mouse IgG. Signal fluctuation of the dual mode sensor chip reader was below 1.2% and 0.8% for SPR and SPCE, respectively. The SPR response in this configuration showed a minimum detection level of 1 μg ml−1, and the SPCE response showed a minimum detection level of 1 ng ml−1 for the same sample. A range of human IgG concentrations in human serum was also analyzed with the dual mode sensor chip. The SPCE measurement is more sensitive than the SPR real-time measurement, and substantially extends the dynamic range of the assay platform, as well as enabling independent measurements of co-localized analytes on the same sensor chip region of interest. Since this assay platform is capable of measuring more than 1000 spatially encoded regions of interest on a 1 cm2 sensor chip, it has the potential for high-content analyses of biological samples with both research and clinical applications.

Graphical abstract: Analysis of immunoarrays using a gold grating-based dual mode surface plasmon-coupled emission (SPCE) sensor chip

Back to tab navigation
Please wait while Download options loads

Publication details

The article was received on 01 Feb 2012, accepted on 13 Mar 2012 and first published on 14 Mar 2012


Article type: Paper
DOI: 10.1039/C2AN35143A
Citation: Analyst, 2012,137, 2574-2581
  •   Request permissions

    Analysis of immunoarrays using a gold grating-based dual mode surface plasmon-coupled emission (SPCE) sensor chip

    J. S. Yuk, G. N. Gibson, J. M. Rice, E. F. Guignon and M. A. Lynes, Analyst, 2012, 137, 2574
    DOI: 10.1039/C2AN35143A

Search articles by author