Jump to main content
Jump to site search

Issue 13, 2010
Previous Article Next Article

Microfabricated thermal modulator for comprehensive two-dimensional micro gas chromatography: design, thermal modeling, and preliminary testing

Author affiliations

Abstract

In comprehensive two-dimensional gas chromatography (GC×GC), a modulator is placed at the juncture between two separation columns to focus and re-inject eluting mixture components, thereby enhancing the resolution and the selectivity of analytes. As part of an effort to develop a μGC×μGC prototype, in this report we present the design, fabrication, thermal operation, and initial testing of a two-stage microscale thermal modulator (μTM). The μTM contains two sequential serpentine Pyrex-on-Si microchannels (stages) that cryogenically trap analytes eluting from the first-dimension column and thermally inject them into the second-dimension column in a rapid, programmable manner. For each modulation cycle (typically 5 s for cooling with refrigeration work of 200 J and 100 ms for heating at 10 W), the μTM is kept approximately at −50 °C by a solid-state thermoelectric cooling unit placed within a few tens of micrometres of the device, and heated to 250 °C at 2800 °C s−1 by integrated resistive microheaters and then cooled back to −50 °C at 250 °C s−1. Thermal crosstalk between the two stages is less than 9%. A lumped heat transfer model is used to analyze the device design with respect to the rates of heating and cooling, power dissipation, and inter-stage thermal crosstalk as a function of Pyrex-membrane thickness, air-gap depth, and stage separation distance. Experimental results are in agreement with trends predicted by the model. Preliminary tests using a conventional capillary column interfaced to the μTM demonstrate the capability for enhanced sensitivity and resolution as well as the modulation of a mixture of alkanes.

Graphical abstract: Microfabricated thermal modulator for comprehensive two-dimensional micro gas chromatography: design, thermal modeling, and preliminary testing

Back to tab navigation

Supplementary files

Publication details

The article was received on 21 Jan 2010, accepted on 26 Feb 2010 and first published on 24 Mar 2010


Article type: Paper
DOI: 10.1039/C001390K
Citation: Lab Chip, 2010,10, 1647-1654
  •   Request permissions

    Microfabricated thermal modulator for comprehensive two-dimensional micro gas chromatography: design, thermal modeling, and preliminary testing

    S. Kim, S. M. Reidy, B. P. Block, K. D. Wise, E. T. Zellers and K. Kurabayashi, Lab Chip, 2010, 10, 1647