Isotopic delta values of molybdenum standard reference and prepared solutions measured by MC-ICP-MS: Proposition for delta zero and secondary references

Abstract

We report the isotopic composition of five molybdenum (Mo) standard reference solutions and four fractions from one of these solutions eluted through anion resin column relative to a sixth reference solution. The reference solutions were National Institute of Standards and Technology (NIST) SRM 3134 (lot#891307), Johnson Matthey Specpure (JMC)-Mo Sie (lot #602332B), JMC-Mo Wen (lot#13989C), Merck (lot#170334), Sigma-Aldrich (lot#207306) and Prolabo. Measurements were conducted using Isoprobe multi collector inductively coupled plasma mass spectrometer (MC-ICP-MS) at the Centre de Recherches Pétrographiques et Géochimiques (France) and Nu Plasma MC-ICP-MS at either the Ecole Normale Supérieure de Lyon (France) or the Laboratory of Isotope Geology in the Ministry of Land and Resources (China). The sample-standard bracketing method was employed to correct the mass bias for Mo isotopes during instrumental measurement. Except for the Merck Mo solution, all the Mo solutions were identical in isotopic composition within error. Although the JMC Mo solution has been used as the internal reference material by various groups, uncertainty may still occur with different lot numbers and availability might be limited. Here, we propose the NIST 3134 Mo solution as a new candidate for delta zero reference material, used for reporting Mo isotopic composition of natural samples. Isotopic compositions for four eluted fractions of the Sigma-Aldrich Mo solution were 2.18‰, 0.98‰, −1.10‰ and −1.95‰ for δ97/95Mo relative to the NIST Mo standard. These values span the range of reported isotopic compositions for natural terrestrial and experimental samples (approximately −0.5‰ to 1.6‰ for δ97/95Mo). We propose these eluted fractions to be used as a secondary reference for Mo isotope measurements. Mo solutions are available at CRPG upon request.

Graphical abstract: Isotopic delta values of molybdenum standard reference and prepared solutions measured by MC-ICP-MS: Proposition for delta zero and secondary references

Article information

Article type
Paper
Submitted
07 Oct 2009
Accepted
15 Jan 2010
First published
04 Feb 2010

J. Anal. At. Spectrom., 2010,25, 716-721

Isotopic delta values of molybdenum standard reference and prepared solutions measured by MC-ICP-MS: Proposition for delta zero and secondary references

H. Wen, J. Carignan, C. Cloquet, X. Zhu and Y. Zhang, J. Anal. At. Spectrom., 2010, 25, 716 DOI: 10.1039/B921060A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements