Jump to main content
Jump to site search

Issue 10, 2010
Previous Article Next Article

Multiplexed, high-throughput analysis of 3D microtissue suspensions

Author affiliations

Abstract

Three-dimensional (3D) tissue models have significantly improved our understanding of structure/function relationships and promise to lead to new advances in regenerative medicine. However, despite the expanding diversity of 3D tissue fabrication methods, approaches for functional assessment have been relatively limited. Here, we describe the fabrication of microtissue (μ-tissue) suspensions and their quantitative evaluation with techniques capable of analyzing large sample numbers and performing multiplexed parallel analysis. We applied this platform to 3D μ-tissues representing multiple stages of liver development and disease including: embryonic stem cells, bipotential hepatic progenitors, mature hepatocytes, and hepatoma cells photoencapsulated in polyethylene glycol hydrogels. Multiparametric μ-tissue cytometry enabled quantitation of fluorescent reporter expression within populations of intact μ-tissues (n ≥ 102–103) and sorting-based enrichment of subsets for subsequent studies. Further, 3D μ-tissues could be implanted in vivo, respond to systemic stimuli, retrieved and quantitatively assessed. In order to facilitate multiplexed ‘pooled’ experimentation, fluorescent labeling strategies were developed and utilized to investigate the impact of μ-tissue composition and exposure to soluble factors. In particular, examination of drug/gene interactions on collections of 3D hepatoma μ-tissues indicated synergistic influence of doxorubicin and siRNA knockdown of the anti-apoptotic gene BCL-XL. Collectively, these studies highlight the broad utility of μ-tissue suspensions as an enabling approach for high n, populational analysis of 3D tissue biology in vitro and in vivo.

Graphical abstract: Multiplexed, high-throughput analysis of 3D microtissue suspensions

Back to tab navigation
Please wait while Download options loads

Supplementary files

Publication details

The article was received on 14 Jun 2010, accepted on 27 Jul 2010 and first published on 01 Sep 2010


Article type: Paper
DOI: 10.1039/C0IB00054J
Citation: Integr. Biol., 2010,2, 517-527
  •   Request permissions

    Multiplexed, high-throughput analysis of 3D microtissue suspensions

    A. A. Chen, G. H. Underhill and S. N. Bhatia, Integr. Biol., 2010, 2, 517
    DOI: 10.1039/C0IB00054J

Search articles by author