Issue 6, 2010

Simultaneous separation and detection of cations and anions on a microfluidic device with suppressed electroosmotic flow and a single injection point

Abstract

A rapid and simultaneous separation of cationic and anionic peptides and proteins in a glass microfluidic device that has been covalently modified with a neutral poly(ethylene glycol) (PEG) coating to minimize protein adsorption is presented. The features of the device allow samples that contain both anions and cations to be introduced from a central flow stream and separated in different channels with different outlets—all in the presence of low electroosmotic flow (EOF) imparted by the PEG coating. The analytes are electrophoretically extracted from a central hydrodynamic stream and electrophoretically separated in two different channels, in which pressure driven flow has been suppressed through the use of hydrodynamic restrictors. Having different outlets for the electrophoretic separation channels that are spatially separated from the injection enables coupling with further downstream functionalities or off-chip detection, such as mass spectrometry. A plug of charged analyte is hydrodynamically pumped to the sampling intersection and anions from the plug migrate electrophoretically toward the anode in one channel while cations migrate toward the cathode in the other channel due to suppressed EOF from the PEG coating. The separations presented here required less than a minute to complete and produced average separation efficiencies of up to about 3,500 plates from a separation length of 2 cm. The extraction efficiency of both cations and anions from the hydrodynamic stream is determined experimentally and compared with a previously reported model that was used to determine anion extraction efficiency. The extraction efficiency is determined to be 87% and 98% for the two sample mixtures analyzed, and the values predicted by the model are within 3.5% of the experimental data. It is anticipated that this basic approach for simultaneous separation of anions and cations with reduced EOF will be integrated into larger microfluidic systems because the design provides separate outlets that can feed downstream processes or linked to off-chip detection.

Graphical abstract: Simultaneous separation and detection of cations and anions on a microfluidic device with suppressed electroosmotic flow and a single injection point

Article information

Article type
Paper
Submitted
20 Oct 2009
Accepted
08 Mar 2010
First published
26 Mar 2010

Analyst, 2010,135, 1351-1359

Simultaneous separation and detection of cations and anions on a microfluidic device with suppressed electroosmotic flow and a single injection point

B. R. Reschke, J. Schiffbauer, B. F. Edwards and A. T. Timperman, Analyst, 2010, 135, 1351 DOI: 10.1039/B921914E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements