Jump to main content
Jump to site search

Issue 8, 2009
Previous Article Next Article

Precise determination of rhenium isotope composition by multi-collector inductively-coupled plasma mass spectrometry

Author affiliations

Abstract

We present rhenium (Re) isotope data for commercially available Re reference materials SRM 989, SRM 3143, and Alfa Aesar Specpure®Re, as well as two Re solutions made in-house from perrhenic acid and zone-refined flattened-wire ribbon from H. Cross Company. Data were generated by MC-ICPMS (Thermo Fisher Scientific NEPTUNE) using standard-bracketing combined with a tungsten (W) external correction. Intermediate measurement precision (i.e. the precision for similar analytical procedures and measurement conditions on the same instrument over time) is ±0.05‰ (2s) for analyte solution concentrations of 20 ng g−1Re and 70 ng g−1W; intermediate precision decreases to ±0.1‰ (2s) when respective analyte concentrations are halved to 10 ng g−1 and 35 ng g−1. The five Re solutions exhibit an isotopic range of 0.29‰, providing the first evidence for stable isotope fractionation of Re. Data are also presented for the Devonian Ohio Shale standard USGS SDO-1; intermediate precision for this natural material (±0.13‰, 2s) is comparable to solution standard precisions at equivalent concentrations (10 ng g−1Re, 35 ng g−1W). Analysis of geochemical materials introduces additional concerns. The low concentration of Re in most materials limits these analyses to Re-rich substrates. Isotopic fractionation occurring during chromatographic purification is nullified by quantitative recovery, and the sample matrix does not introduce fractionation artifacts. Isobaric interference from radiogenic 187Os can be effectively removed by sparging sample solutions prior to analysis.

Graphical abstract: Precise determination of rhenium isotope composition by multi-collector inductively-coupled plasma mass spectrometry

Back to tab navigation
Please wait while Download options loads

Publication details

The article was received on 21 Oct 2008, accepted on 23 Apr 2009 and first published on 27 May 2009


Article type: Paper
DOI: 10.1039/B818631F
Citation: J. Anal. At. Spectrom., 2009,24, 1069-1078
  •   Request permissions

    Precise determination of rhenium isotope composition by multi-collector inductively-coupled plasma mass spectrometry

    C. A. Miller, B. Peucker-Ehrenbrink and L. Ball, J. Anal. At. Spectrom., 2009, 24, 1069
    DOI: 10.1039/B818631F

Search articles by author