Issue 4, 2008

Determination of arsenic species in human urine using high performance liquid chromatography (HPLC) coupled with inductively coupled plasma mass spectrometry (ICP-MS)

Abstract

A speciation technique for arsenic (As) has been applied using ion pair reverse phase-high performance liquid chromatography coupled to inductively coupled plasma mass spectrometry (RP-HPLC-ICP-MS). Six As-species (arsenite, arsenate, dimethylarsinic acid, dimethylarsinous acid, monomethylarsonic acid and monomethylarsonous acid) have been separated with isocratic elution within less than 6 minutes. A cation exchange column was used for separation of AsB, AsC, Tetra (Me4As+) and TMAsO. The As chemical form and oxidation state is highly important in respect to toxicity; therefore total As-determination is insufficient for a complete toxicological evaluation and risk assessment. Arsenic-speciation has been studied on urine samples of children from an As-affected area in the Iron Quadrangle, Brazil. DMAsV and MMAsV were the major urinary metabolites in these samples. The mean value for total As-concentration of all samples (n = 15) was 26.3 ng As mL−1 with a range of 16.1 to 55.2 ng As mL−1. TMAsO and AsC (arsenocholine) were not detected in this study. In most samples, monomethylarsonous acid [MMAsIII] was detected up to 2.0 ng As mL−1. DMAsIII was not detected at any time, most probably due to volatilisation and some oxidation to DMAsV. The chromatographic recoveries, calculated from ([sum(species) × 100]/total As in urine samples), ranged from 77.4 to 94.9%. This work also contributes to the pertinent discussion regarding the reliability of MMAsIII/DMAsIII speciation in urine.

Graphical abstract: Determination of arsenic species in human urine using high performance liquid chromatography (HPLC) coupled with inductively coupled plasma mass spectrometry (ICP-MS)

Article information

Article type
Paper
Submitted
05 Dec 2007
Accepted
23 Jan 2008
First published
15 Feb 2008

J. Anal. At. Spectrom., 2008,23, 544-549

Determination of arsenic species in human urine using high performance liquid chromatography (HPLC) coupled with inductively coupled plasma mass spectrometry (ICP-MS)

S. Rabieh, A. V. Hirner and J. Matschullat, J. Anal. At. Spectrom., 2008, 23, 544 DOI: 10.1039/B718840D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements