Issue 6, 2005
Previous Article Next Article

Hyphenation of flow injection on-line preconcentration and ICP-MS for the rapid determination of 226Ra in natural waters

Author affiliations

Abstract

A novel, sensitive, and rapid method is developed for the preconcentration/separation of 226Ra in natural waters using a flow injection (FI) design based on a sequential on-line ion exchange preconcentration coupled with ICP-MS. 226Ra is extracted using an Ln resin (HDEHP) from the sample at pH 10.6 in the presence of ethylenediamine tetraacetic acid (EDTA) diammonium salt, whereas Ca and Mg, which form stable complexes with EDTA, are not retained on the column. Quantitative elution of 226Ra from the Ln resin is achieved using 5 M HNO3. The separation of Ra from Ba and Sr is subsequently performed by the selective retention of Sr and Ba on an Sr*Spec resin, placed between the Ln resin and the Apex-Q system. In addition to being accurate and rapid for 226Ra determination, this method is effective in eliminating spectral (88Sr138Ba) and non-spectral (Ca, Mg) interferences. Using a 20 mL sample, a detection limit (3σ) of 457 fg L−1 (16.92 mBq L−1) was obtained with a sample throughput of 3.5 samples h−1. The precision for 6 replicate measurements of 5 pg L−1 (185.18 mBq L−1) 226Ra was better than 4%. The method was applied to the analysis of natural waters, where the concentration of 226Ra was found to be in the range 1.2 to 2.4 pg L−1 (44.4 to 88.8 mBq L−1), lower than the maximum acceptable concentration (MAC) for 226Ra of 16.2 pg L−1 (600 mBq L−1), recommended in the Guideline for Canadian Drinking Water Quality.

Graphical abstract: Hyphenation of flow injection on-line preconcentration and ICP-MS for the rapid determination of 226Ra in natural waters

Back to tab navigation
Please wait while Download options loads

Publication details

The article was received on 28 Sep 2004, accepted on 16 Mar 2005 and first published on 15 Apr 2005


Article type: Paper
DOI: 10.1039/B414812F
Citation: J. Anal. At. Spectrom., 2005,20, 523-528
  •   Request permissions

    Hyphenation of flow injection on-line preconcentration and ICP-MS for the rapid determination of 226Ra in natural waters

    K. Benkhedda, D. Larivière, S. Scott and D. Evans, J. Anal. At. Spectrom., 2005, 20, 523
    DOI: 10.1039/B414812F

Search articles by author